GAJDAR, J, Tomáš GONĚC, J JAMPILEK, Marie BRÁZDOVÁ, Z BABKOVA, Miroslav FOJTA, J BAREK a J FISCHER. Voltammetry of a Novel Antimycobacterial Agent 1-Hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide in a Single Drop of a Solution. Electroanalysis. WEINHEIM: WILEY-VCH Verlag GmbH, 2018, roč. 30, č. 1, s. 38-47. ISSN 1040-0397. Dostupné z: https://dx.doi.org/10.1002/elan.201700547.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Voltammetry of a Novel Antimycobacterial Agent 1-Hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide in a Single Drop of a Solution
Autoři GAJDAR, J, Tomáš GONĚC, J JAMPILEK, Marie BRÁZDOVÁ, Z BABKOVA, Miroslav FOJTA, J BAREK a J FISCHER.
Vydání Electroanalysis, WEINHEIM, WILEY-VCH Verlag GmbH, 2018, 1040-0397.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 2.691
Doi http://dx.doi.org/10.1002/elan.201700547
UT WoS 000419697700007
Klíčová slova anglicky Hydroxynaphthalene-2-carboxanilide; Microcell; Single drop analysis; Voltammetry
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: PharmDr. Tomáš Goněc, Ph.D., učo 39112. Změněno: 9. 3. 2021 23:48.
Anotace
The aim of this study is the development of a miniaturized voltammetric method for the determination of an antimycobacterial agent 1-hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide (HNN) in a single drop (20L) of a solution by cathodic and anodic voltammetry at a glassy carbon electrode. Cyclic voltammetry was used to investigate its redox properties followed by the optimization of differential pulse voltammetric determination in a regular 10mL volume. The optimal medium for the analytical application of both cathodic and anodic voltammetry was found to be Britton-Robinson buffer pH7.0 and dimethyl sulfoxide (9:1, v/v). HNN gave one cathodic peak at around -0.6V and one anodic peak at around +0.2V vs. Ag|AgCl (3molL(-1) KCl) reference electrode. Determination of HNN in a 10mL volume gave the limit of quantification around 10nmolL(-1) by both adsorptive stripping anodic and cathodic voltammetry. Afterwards, miniaturized voltammetric methods in a single drop of solution (20L) were investigated. This approach requested some modifications of the cell design and voltammetric procedures. A novel method of removing dissolved oxygen in a single drop had to be developed and tested. Developed miniaturized voltammetric methods gave parameters comparable to the determination of HNN in 10mL. The applicability of the miniaturized method was verified by the determination of HNN in a drop of a bacterial growth medium.
VytisknoutZobrazeno: 25. 4. 2024 08:41