VAN DER MULLEN, Joost, Mariana ATANASOVA, Adam OBRUSNÍK a Lenka ZAJÍČKOVÁ. Thomson scattering versus modeling of the microwave plasma torch: a long standing discrepancy almost solved. Journal of analytical atomic spectrometry. Cambridge: Royal Society of Chemistry, roč. 35, č. 9, s. 2064-2074. ISSN 0267-9477. doi:10.1039/d0ja00161a. 2020.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Thomson scattering versus modeling of the microwave plasma torch: a long standing discrepancy almost solved
Autoři VAN DER MULLEN, Joost, Mariana ATANASOVA, Adam OBRUSNÍK (203 Česká republika, domácí) a Lenka ZAJÍČKOVÁ (203 Česká republika, domácí).
Vydání Journal of analytical atomic spectrometry, Cambridge, Royal Society of Chemistry, 2020, 0267-9477.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10305 Fluids and plasma physics
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.023
Kód RIV RIV/00216224:14310/20:00117958
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1039/d0ja00161a
UT WoS 000569703600027
Klíčová slova anglicky plasma torches; light emission; microwaves
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 6. 3. 2024 14:51.
Anotace
The characterization of plasmas gives much more insight if the results of modeling are compared with those of experiments. In the past, several modeling-experiment studies were performed on the microwave plasma torch (MPT). For the modeling a Global Plasma Model (GPM) was employed and for the experiment Thomson scattering (TS) was used. The same GPM-TS comparison was successfully applied to several other, more robust plasmas. However for the MPT it was found that the comparison led to severe discrepancies. The most salient feature was that the value of the electron temperature,T-e, found by TS, was substantially higher than what GPMs predicted. Several attempts were undertaken to solve this problem by refining the model and its most important input: the gradient of the electron density. The attention for the model implied that the TS technique was not scrutinized sufficiently. Recently it was discovered that the outcome of TS is very sensitive to the spectral fitting procedure. In the past this was carried out by employing the calibrated intensity using Gaussian fitting. However, a procedure based on the fitting of the spectral shape by using modified Gaussian fitting gives better results and leads to a lowerT(e)value, more in the range of the GPM results. This paper discusses the background of the GPM and gives the basis of TS fitting procedures and an analysis of the systematic error that can be made when TS is performed on filamentary MPT-like plasmas.
Návaznosti
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
VytisknoutZobrazeno: 19. 4. 2024 20:20