FERENT, I. F., A. MESTER, Ota HLINOMAZ, Ladislav GROCH, Michal REZEK, Jan SITAR, Jiří SEMÉNKA, Martin NOVÁK a I. S. BENEDEK. Intracoronary Imaging for Assessment of Vascular Healing and Stent Follow-up in Bioresorbable Vascular Scaffolds. CURRENT MEDICAL IMAGING. SHARJAH: BENTHAM SCIENCE PUBL LTD, 2020, roč. 16, č. 2, s. 123-134. ISSN 1573-4056. Dostupné z: https://dx.doi.org/10.2174/1573405614666180604093621.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Intracoronary Imaging for Assessment of Vascular Healing and Stent Follow-up in Bioresorbable Vascular Scaffolds
Autoři FERENT, I. F., A. MESTER (garant), Ota HLINOMAZ (203 Česká republika, domácí), Ladislav GROCH (203 Česká republika, domácí), Michal REZEK (203 Česká republika, domácí), Jan SITAR (203 Česká republika, domácí), Jiří SEMÉNKA (203 Česká republika, domácí), Martin NOVÁK (203 Česká republika, domácí) a I. S. BENEDEK.
Vydání CURRENT MEDICAL IMAGING, SHARJAH, BENTHAM SCIENCE PUBL LTD, 2020, 1573-4056.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30224 Radiology, nuclear medicine and medical imaging
Stát vydavatele Spojené arabské emiráty
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 0.858
Kód RIV RIV/00216224:14110/20:00118313
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.2174/1573405614666180604093621
UT WoS 000509481900004
Klíčová slova anglicky Coronary stents; vascular scaffold; intracoronary imaging; polymer-coated stent; bioresorbable; stent struts
Štítky 14110115, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 3. 3. 2021 09:48.
Anotace
Bioresorbable Vascular Scaffolds (BVS) are polymer-based materials implanted in the coronary arteries in order to treat atherosclerotic lesions, based on the concept that once the lesion has been treated, the material of the implanted stent will undergo a process of gradual resorption that will leave, in several years, the vessel wall smooth, free of any foreign material and with its vasomotion restored. However, after the first enthusiastic reports on the efficacy of BVSs, the recently published trials demonstrated disappointing results regarding long-term patency following BVS implantation. which were mainly attributed to technical deficiencies during the stenting pmcedure. Intracoronary imaging could play a crucial role for helping the operator to correctly implant a BVS into the coronary artery, as well as providing relevant information in the follow-up period. This review aims to summarize the role of intracoronary imaging in the follow-up of coronary stents, with a particular emphasis on the role of intravascular ultrasound and optical coherence tomography for procedural guidance during stent implantation and also for follow-up of bioabsorbable scaffolds.