Detailed Information on Publication Record
2020
Protective aspects in contactless infrared thermography fever screening
BERNARD, Vladan, Erik STAFFA, Aleš BOUREK, Marek DOSTÁL, Vojtěch MORNSTEIN et. al.Basic information
Original name
Protective aspects in contactless infrared thermography fever screening
Authors
BERNARD, Vladan (203 Czech Republic, guarantor, belonging to the institution), Erik STAFFA (203 Czech Republic, belonging to the institution), Aleš BOUREK (203 Czech Republic, belonging to the institution), Marek DOSTÁL (203 Czech Republic, belonging to the institution), Vojtěch MORNSTEIN (203 Czech Republic, belonging to the institution) and Jana POKORNÁ (203 Czech Republic, belonging to the institution)
Edition
Lékař a technika, ČVUT, Fakulta biomedicínského inženýrství, 2020, 0301-5491
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
20601 Medical engineering
Country of publisher
Czech Republic
Confidentiality degree
není předmětem státního či obchodního tajemství
References:
RIV identification code
RIV/00216224:14110/20:00121310
Organization unit
Faculty of Medicine
Keywords in English
febrile screening; infrared thermography; protective foil
Tags
Tags
International impact, Reviewed
Změněno: 17/5/2022 08:55, Mgr. Tereza Miškechová
Abstract
V originále
Main symptoms found in patients with same diseases as for example COVID-19 is febrile. The infrared thermography (IRT) represents a fast measurement in case of screening in public places. One of the limitations of IRT is the resolution of sensor, which has close connection with the distance between camera and ROI. To maximize the effectivity of resolution of the camera is to reduce the distance from the object. The aim of presented study showed the possibility how to protect the camera or medical staff that operates the device against potential infection or contamination from the person with infection. Two protective foils of different thickness (40microm; 9microm) were tested as a barrier between the IRT and the ROI (black body model and human face). Even though the results have shown that the transparent foils decrease linearly the measured value of the temperature, it can be used as a protective barrier between IRT and the object if an appropriate recalculation is done during analysis of IRT images. Results are acceptable in the case of 9microm foil especially. The authors see this possibility as a minor concession from IRT standards but as a great help in health protection. The transparent foil can be used as protective barrier of the infrared camera.
Links
MUNI/A/1369/2019, interní kód MU |
| ||
MUNI/A/1706/2020, interní kód MU |
|