Informační systém MU
MILITARU, Sebastian, Roman PANOVSKÝ, Vincent HANET, Mihaela Silvia AMZULESCU, Hélène LANGET, Mary Mojica PISCIOTTI, Anne-Catherine POULEUR, Jean-Louis J. VANOVERSCHELDE and Bernhard L. GERBER. Multivendor comparison of global and regional 2D cardiovascular magnetic resonance feature tracking strains vs tissue tagging at 3T. Journal of Cardiovascular Magnetic Resonance. London: BMC, 2021, vol. 23, No 1, p. 1-16. ISSN 1097-6647. Available from: https://dx.doi.org/10.1186/s12968-021-00742-3.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Multivendor comparison of global and regional 2D cardiovascular magnetic resonance feature tracking strains vs tissue tagging at 3T
Authors MILITARU, Sebastian, Roman PANOVSKÝ (203 Czech Republic, belonging to the institution), Vincent HANET, Mihaela Silvia AMZULESCU, Hélène LANGET, Mary Mojica PISCIOTTI, Anne-Catherine POULEUR, Jean-Louis J. VANOVERSCHELDE and Bernhard L. GERBER (guarantor).
Edition Journal of Cardiovascular Magnetic Resonance, London, BMC, 2021, 1097-6647.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 30201 Cardiac and Cardiovascular systems
Country of publisher United Kingdom of Great Britain and Northern Ireland
Confidentiality degree is not subject to a state or trade secret
WWW URL
Impact factor Impact factor: 6.903
RIV identification code RIV/00216224:14110/21:00121572
Organization unit Faculty of Medicine
Doi http://dx.doi.org/10.1186/s12968-021-00742-3
UT WoS 000656236800002
Keywords in English Feature tracking; Tagging; Magnetic resonance imaging; Strain
Tags 14110115, rivok
Tags International impact, Reviewed
Changed by Changed by: Mgr. Tereza Miškechová, učo 341652. Changed: 15/6/2021 13:29.
Abstract
Background Cardiovascular magnetic resonance (CMR) 2D feature tracking (FT) left ventricular (LV) myocardial strain has seen widespread use to characterize myocardial deformation. Yet, validation of CMR FT measurements remains scarce, particularly for regional strain. Therefore, we aimed to perform intervendor comparison of 3 different FT software against tagging. Methods In 61 subjects (18 healthy subjects, 18 patients with chronic myocardial infarction, 15 with dilated cardiomyopathy, and 10 with LV hypertrophy due to hypertrophic cardiomyopathy or aortic stenosis) were prospectively compared global (G) and regional transmural peak-systolic Lagrangian longitudinal (LS), circumferential (CS) and radial strains (RS) by 3 FT software (cvi42, Segment, and Tomtec) among each other and with tagging at 3T. We also evaluated the ability of regional LS, CS, and RS by different FT software vs tagging to identify late gadolinium enhancement (LGE) in the 18 infarct patients. Results GLS and GCS by all 3 software had an excellent agreement among each other (ICC = 0.94-0.98 for GLS and ICC = 0.96-0.98 for GCS respectively) and against tagging (ICC = 0.92-0.94 for GLS and ICC = 0.88-0.91 for GCS respectively), while GRS showed inconsistent agreement between vendors (ICC 0.10-0.81). For regional LS, the agreement was good (ICC = 0.68) between 2 vendors but less vs the 3(rd) (ICC 0.50-0.59) and moderate to poor (ICC 0.44-0.47) between all three FT software and tagging. Also, for regional CS agreement between 2 software was higher (ICC = 0.80) than against the 3rd (ICC = 0.58-0.60), and both better agreed with tagging (ICC = 0.70-0.72) than the 3rd (ICC = 0.57). Regional RS had more variation in the agreement between methods ranging from good (ICC = 0.75) to poor (ICC = 0.05). Finally, the accuracy of scar detection by regional strains differed among the 3 FT software. While the accuracy of regional LS was similar, CS by one software was less accurate (AUC 0.68) than tagging (AUC 0.80, p < 0.006) and RS less accurate (AUC 0.578) than the other two (AUC 0.76 and 0.73, p < 0.02) to discriminate segments with LGE. Conclusions We confirm good agreement of CMR FT and little intervendor difference for GLS and GCS evaluation, with variable agreement for GRS. For regional strain evaluation, intervendor difference was larger, especially for RS, and the diagnostic performance varied more substantially among different vendors for regional strain analysis.
Displayed: 23/8/2024 22:15