Informační systém MU
RUBEIS, De., G. NAPP, A. E. SCHLATTMANN, P. GELEIJNS, J. LAULE, M. DREGER, H. KOFOED, K. SORGAARD, M. ENGSTROM, T. TILSTED, H. H. BOI, A. PORCU, M. COSSA, S. RODRIGUEZ-PALOMARES, J. F. VALENTE, F. X. ROQUE, A. FEUCHTNER, G. PLANK, F. STECHOVSKY, C. ADLA, T. SCHROEDER, S. ZELESNY, T. GUTBERLET, M.. WOINKE, M. KAROLYI, M. KARADY, J. DONNELLY, P. BALL, P. DODD, J. HENSEY, M. MANCONE, M. CECCACCI, A. BERZINA, M. ZVAIGZNE, L. SAKALYTE, G. BASEVICIUS, A. ILNICKA-SUCKIEL, M. KUSMIERZ, D. FARIA, R. GAMA-RIBEIRO, V. BENEDEK, I. BENEDEK, T. ADJIC, F. CANKOVIC, M. BERRY, C. DELLES, C. THWAITE, E. DAVIS, G. KNUUTI, J. PIETILA, M. KEPKA, C. KRUK, M. VIDAKOVIC, R. NESKOVIC, A. N. LECUMBERRI, I. GONZALES, I. D. RUZSICS, B. FISHER, M. DEWEY a M. FRANCONE. Pilot study of the multicentre DISCHARGE Trial: image quality and protocol adherence results of computed tomography and invasive coronary angiography. European Radiology. New York: Springer, 2020, roč. 30, č. 4, s. 1997-2009. ISSN 0938-7994. Dostupné z: https://dx.doi.org/10.1007/s00330-019-06522-z.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Pilot study of the multicentre DISCHARGE Trial: image quality and protocol adherence results of computed tomography and invasive coronary angiography
Autoři RUBEIS, De., G. NAPP, A. E. SCHLATTMANN, P. GELEIJNS, J. LAULE, M. DREGER, H. KOFOED, K. SORGAARD, M. ENGSTROM, T. TILSTED, H. H. BOI, A. PORCU, M. COSSA, S. RODRIGUEZ-PALOMARES, J. F. VALENTE, F. X. ROQUE, A. FEUCHTNER, G. PLANK, F. STECHOVSKY, C. ADLA, T. SCHROEDER, S. ZELESNY, T. GUTBERLET, M.. WOINKE, M. KAROLYI, M. KARADY, J. DONNELLY, P. BALL, P. DODD, J. HENSEY, M. MANCONE, M. CECCACCI, A. BERZINA, M. ZVAIGZNE, L. SAKALYTE, G. BASEVICIUS, A. ILNICKA-SUCKIEL, M. KUSMIERZ, D. FARIA, R. GAMA-RIBEIRO, V. BENEDEK, I. BENEDEK, T. ADJIC, F. CANKOVIC, M. BERRY, C. DELLES, C. THWAITE, E. DAVIS, G. KNUUTI, J. PIETILA, M. KEPKA, C. KRUK, M. VIDAKOVIC, R. NESKOVIC, A. N. LECUMBERRI, I. GONZALES, I. D. RUZSICS, B. FISHER, M. DEWEY a M. FRANCONE.
Vydání European Radiology, New York, Springer, 2020, 0938-7994.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30230 Other clinical medicine subjects
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 5.315
Doi http://dx.doi.org/10.1007/s00330-019-06522-z
UT WoS 000519659200020
Klíčová slova anglicky Medical imaging; CT angiography; Angiography; coronary; Coronary artery disease; Trial protocols
Štítky Excelence Science, FN MOTOL, INT, RIV, user
Změnil Změnila: Bc. Hana Vladíková, BBA, učo 244692. Změněno: 7. 12. 2021 12:59.
Anotace
Objective To implement detailed EU cardiac computed tomography angiography (CCTA) quality criteria in the multicentre DISCHARGE trial (FP72007-2013, EC-GA 603266), we reviewed image quality and adherence to CCTA protocol and to the recommendations of invasive coronary angiography (ICA) in a pilot study. Materials and methods From every clinical centre, imaging datasets of three patients per arm were assessed for adherence to the inclusion/exclusion criteria of the pilot study, predefined standards for the CCTA protocol and ICA recommendations, image quality and non-diagnostic (NDX) rate. These parameters were compared via multinomial regression and ANOVA. If a site did not reach the minimum quality level, additional datasets had to be sent before entering into the final accepted database (FADB). Results We analysed 226 cases (150 CCTA/76 ICA). The inclusion/exclusion criteria were not met by 6 of the 226 (2.7%) datasets. The predefined standard was not met by 13 of 76 ICA datasets (17.1%). This percentage decreased between the initial CCTA database and the FADB (multinomial regression, 53 of 70 vs 17 of 75 [76%] vs [23%]). The signal-to-noise ratio and contrast-to-noise ratio of the FADB did not improve significantly (ANOVA, p = 0.20; p = 0.09). The CTA NDX rate was reduced, but not significantly (initial CCTA database 15 of 70 [21.4%]) and FADB 9 of 75 [12%]; p = 0.13). Conclusion We were able to increase conformity to the inclusion/exclusion criteria and CCTA protocol, improve image quality and decrease the CCTA NDX rate by implementing EU CCTA quality criteria and ICA recommendations.
Návaznosti
90128, velká výzkumná infrastrukturaNázev: CZECRIN III
Zobrazeno: 30. 4. 2024 11:15