MALÁ, Miriam, Petra ITTERHEIMOVÁ, Lukáš HOMOLA, Jana VINOHRADSKÁ a Petr KUBÁŇ. 3D Printed Skin-Wash Sampler for Sweat Sampling in Cystic Fibrosis Diagnosis Using Capillary Electrophoretic Ion Ratio Analysis. Separations. Basel: MDPI, 2021, roč. 8, č. 12, s. 1-10. ISSN 2297-8739. Dostupné z: https://dx.doi.org/10.3390/separations8120234.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název 3D Printed Skin-Wash Sampler for Sweat Sampling in Cystic Fibrosis Diagnosis Using Capillary Electrophoretic Ion Ratio Analysis
Autoři MALÁ, Miriam (203 Česká republika, domácí), Petra ITTERHEIMOVÁ (203 Česká republika, domácí), Lukáš HOMOLA (203 Česká republika, domácí), Jana VINOHRADSKÁ (203 Česká republika, domácí) a Petr KUBÁŇ (203 Česká republika, garant, domácí).
Vydání Separations, Basel, MDPI, 2021, 2297-8739.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.344
Kód RIV RIV/00216224:14110/21:00120173
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.3390/separations8120234
UT WoS 000737166500001
Klíčová slova anglicky cystic fibrosis; sweat sampling; skin-wash; capillary electrophoresis; contactless conductivity detection; ion ratio
Štítky 14110212, 14110318, podil, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 4. 3. 2022 10:16.
Anotace
Sweat chloride analysis is one of the important approaches in cystic fibrosis diagnosis. The commonly used Macroduct method to acquire sweat samples is semi-invasive, time consuming and expensive. Furthermore, this method often fails to collect a sufficient amount of sweat in newborns due to the insufficient sweating rate. In this work, we present a novel, simple, 3D-printed sampling device that is used to collect sweat specimens completely noninvasively in less than one minute. The device has a flow-through channel adjacent to the skin surface, through which 500 µL of deionized water is flushed and the spontaneously formed sweat on the skin in the channel area is washed into a plastic vial. The developed skin-wash procedure is a single step operation, is completely noninvasive and it always produces a sweat specimen. The ions from the skin-wash are subsequently analyzed by capillary electrophoresis with contactless conductivity detection and selected ion ratio (Cl−/K+) or ((Cl− + Na+)/K+) is used as a cut-off value to diagnose cystic fibrosis patients with sensitivity and specificity comparable to the conventional Macroduct method.
Návaznosti
NV18-08-00189, projekt VaVNázev: Nový postup diagnostiky cystické fibrózy založený na iontových poměrech v neinvazivně získaných vzorcích
Investor: Ministerstvo zdravotnictví ČR, Nový postup diagnostiky cystické fibrózy založený na iontových poměrech v neinvazivně získaných vzorcích
VytisknoutZobrazeno: 25. 4. 2024 18:14