Other formats:
BibTeX
LaTeX
RIS
@article{1818481, author = {Pásek, Michal and Šimurda, Jiří and Bébarová, Markéta and Christe, Georges}, article_location = {Cambridge}, article_number = {14}, doi = {http://dx.doi.org/10.1242/jcs.258228}, keywords = {Cardiac myocyte; t-tubules; Na-Ca exchanger; Membrane current density; Log-normal distribution; Monte Carlo simulation}, language = {eng}, issn = {0021-9533}, journal = {Journal of Cell Science}, title = {Divergent estimates of the ratio between Na+-Ca2+ current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes}, url = {https://journals.biologists.com/jcs/article-abstract/134/14/jcs258228/271058/Divergent-estimates-of-the-ratio-between-Na-Ca2?redirectedFrom=fulltext}, volume = {134}, year = {2021} }
TY - JOUR ID - 1818481 AU - Pásek, Michal - Šimurda, Jiří - Bébarová, Markéta - Christe, Georges PY - 2021 TI - Divergent estimates of the ratio between Na+-Ca2+ current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes JF - Journal of Cell Science VL - 134 IS - 14 SP - 1-7 EP - 1-7 PB - Company of Biologists Ltd. SN - 00219533 KW - Cardiac myocyte KW - t-tubules KW - Na-Ca exchanger KW - Membrane current density KW - Log-normal distribution KW - Monte Carlo simulation UR - https://journals.biologists.com/jcs/article-abstract/134/14/jcs258228/271058/Divergent-estimates-of-the-ratio-between-Na-Ca2?redirectedFrom=fulltext N2 - The ratio between Na+-Ca2+ exchange current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes (J(NaCa)-ratio) estimated from electrophysiological data published to date yields strikingly different values between 1.7 and nearly 40. Possible reasons for such divergence were analysed by Monte Carlo simulations assuming both normal and log-normal distribution of the measured data. The confidence intervals CI95 of themean J(NaCa)-ratios computed from the reported data showed an overlap of values between 1 and 3, and between 0.3 and 4.3 in the case of normal and log-normal distribution, respectively. Further analyses revealed that the published high values likely result from a large scatter of data due to transmural differences in J(NaCa), dispersion of cell membrane capacitances and variability in incomplete detubulation. Taking into account the asymmetric distribution of the measured data, the reduction of mean current densities after detubulation and the substantiallysmaller CI95 of lower values of the mean J(NaCa)-ratio, the values between 1.6 and 3.2 may be considered as the most accurate estimates. This implies that 40 to 60% of Na+-Ca2+ exchanger is located at the t-tubular membrane of adult rat ventricular cardiomyocytes. ER -
PÁSEK, Michal, Jiří ŠIMURDA, Markéta BÉBAROVÁ and Georges CHRISTE. Divergent estimates of the ratio between Na+-Ca2+ current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes. \textit{Journal of Cell Science}. Cambridge: Company of Biologists Ltd., 2021, vol.~134, No~14, p.~1-7. ISSN~0021-9533. Available from: https://dx.doi.org/10.1242/jcs.258228.
|