KOVÁŘOVÁ, Anežka, Martin GAJDOŠ, Ivan REKTOR a Michal MIKL. Contribution of the multi-echo approach in accelerated functional magnetic resonance imaging multiband acquisition. Human Brain mapping. USA: WILEY, roč. 43, č. 3, s. 955-973. ISSN 1065-9471. doi:10.1002/hbm.25698. 2022.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Contribution of the multi-echo approach in accelerated functional magnetic resonance imaging multiband acquisition
Autoři KOVÁŘOVÁ, Anežka (203 Česká republika, domácí), Martin GAJDOŠ (203 Česká republika, domácí), Ivan REKTOR (203 Česká republika, domácí) a Michal MIKL (203 Česká republika, garant, domácí).
Vydání Human Brain mapping, USA, WILEY, 2022, 1065-9471.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30103 Neurosciences
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.800
Kód RIV RIV/00216224:14740/22:00125432
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1002/hbm.25698
UT WoS 000712875500001
Klíčová slova anglicky acquisition acceleration; BOLD; multi-echo fMRI; simultaneous multi-slice imaging; TE dependence
Štítky 14110127, CF MAFIL, podil, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 3. 2. 2023 13:12.
Anotace
We wanted to verify the effect of combining multi-echo (ME) functional magnetic resonance imaging (fMRI) with slice acceleration in simultaneous multi-slice acquisition. The aim was to shed light on the benefits of multiple echoes for various acquisition settings, especially for levels of slice acceleration and flip angle. Whole-brain ME fMRI data were obtained from 26 healthy volunteers (using three echoes; seven runs with slice acceleration 1, 4, 6, and 8; and two different flip angles for each of the first three acceleration factors) and processed as single-echo (SE) data and ME data based on optimal combinations weighted by the contrast-to-noise ratio. Global metrics (temporal signal-to-noise ratio, signal-to-noise separation, number of active voxels, etc.) and local characteristics in regions of interest were used to evaluate SE and ME data. ME results outperformed SE results in all runs; the differences became more apparent for higher acceleration, where a significant decrease in data quality is observed. ME fMRI can improve the observed data quality metrics over SE fMRI for a wide range of accelerated fMRI acquisitions.
Návaznosti
EF16_013/0001775, projekt VaVNázev: Modernizace a podpora výzkumných aktivit národní infrastruktury pro biologické a medicínské zobrazování Czech-BioImaging
LM2015062, projekt VaVNázev: Národní infrastruktura pro biologické a medicínské zobrazování