J 2022

Contribution of the multi-echo approach in accelerated functional magnetic resonance imaging multiband acquisition

KOVÁŘOVÁ, Anežka, Martin GAJDOŠ, Ivan REKTOR and Michal MIKL

Basic information

Original name

Contribution of the multi-echo approach in accelerated functional magnetic resonance imaging multiband acquisition

Authors

KOVÁŘOVÁ, Anežka (203 Czech Republic, belonging to the institution), Martin GAJDOŠ (203 Czech Republic, belonging to the institution), Ivan REKTOR (203 Czech Republic, belonging to the institution) and Michal MIKL (203 Czech Republic, guarantor, belonging to the institution)

Edition

Human Brain mapping, USA, WILEY, 2022, 1065-9471

Other information

Language

English

Type of outcome

Článek v odborném periodiku

Field of Study

30103 Neurosciences

Country of publisher

United States of America

Confidentiality degree

není předmětem státního či obchodního tajemství

References:

URL

Impact factor

Impact factor: 4.800

RIV identification code

RIV/00216224:14740/22:00125432

Organization unit

Central European Institute of Technology

DOI

http://dx.doi.org/10.1002/hbm.25698

UT WoS

000712875500001

Keywords in English

acquisition acceleration; BOLD; multi-echo fMRI; simultaneous multi-slice imaging; TE dependence

Tags

14110127, CF MAFIL, podil, rivok

Tags

International impact, Reviewed
Změněno: 17/10/2024 08:48, Mgr. Adéla Pešková

Abstract

V originále

We wanted to verify the effect of combining multi-echo (ME) functional magnetic resonance imaging (fMRI) with slice acceleration in simultaneous multi-slice acquisition. The aim was to shed light on the benefits of multiple echoes for various acquisition settings, especially for levels of slice acceleration and flip angle. Whole-brain ME fMRI data were obtained from 26 healthy volunteers (using three echoes; seven runs with slice acceleration 1, 4, 6, and 8; and two different flip angles for each of the first three acceleration factors) and processed as single-echo (SE) data and ME data based on optimal combinations weighted by the contrast-to-noise ratio. Global metrics (temporal signal-to-noise ratio, signal-to-noise separation, number of active voxels, etc.) and local characteristics in regions of interest were used to evaluate SE and ME data. ME results outperformed SE results in all runs; the differences became more apparent for higher acceleration, where a significant decrease in data quality is observed. ME fMRI can improve the observed data quality metrics over SE fMRI for a wide range of accelerated fMRI acquisitions.

Links

EF16_013/0001775, research and development project
Name: Modernizace a podpora výzkumných aktivit národní infrastruktury pro biologické a medicínské zobrazování Czech-BioImaging
LM2015062, research and development project
Name: Národní infrastruktura pro biologické a medicínské zobrazování
Investor: Ministry of Education, Youth and Sports of the CR
LM2018129, research and development project
Name: Národní infrastruktura pro biologické a medicínské zobrazování Czech-BioImaging
Investor: Ministry of Education, Youth and Sports of the CR
90062, large research infrastructures
Name: Czech-BioImaging
90129, large research infrastructures
Name: Czech-BioImaging II
Displayed: 18/10/2024 21:41