JADCZYK, Tomasz, Jiří WOLF, Martin PEŠL, Filip SOUČEK, František LEHAR, Jiří JEŽ, Tomáš KULÍK, Bohdan TYSHCHENKO, Silvie BĚLAŠKOVÁ, Petr OUŘEDNÍČEK, Guido CALUORI, Miroslav NOVÁK and Zdeněk STÁREK. Reduced Radiation Exposure Protocol during Computer Tomography of the Left Atrium Prior to Catheter Ablation in Patients with Atrial Fibrillation. Diagnostics. Basel: MDPI, 2022, vol. 12, No 3, p. 1-12. ISSN 2075-4418. Available from: https://dx.doi.org/10.3390/diagnostics12030612.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Reduced Radiation Exposure Protocol during Computer Tomography of the Left Atrium Prior to Catheter Ablation in Patients with Atrial Fibrillation
Authors JADCZYK, Tomasz, Jiří WOLF (203 Czech Republic), Martin PEŠL (203 Czech Republic, belonging to the institution), Filip SOUČEK (203 Czech Republic), František LEHAR (203 Czech Republic), Jiří JEŽ (203 Czech Republic), Tomáš KULÍK (203 Czech Republic), Bohdan TYSHCHENKO, Silvie BĚLAŠKOVÁ (203 Czech Republic, belonging to the institution), Petr OUŘEDNÍČEK (203 Czech Republic, belonging to the institution), Guido CALUORI (380 Italy, belonging to the institution), Miroslav NOVÁK (203 Czech Republic) and Zdeněk STÁREK (203 Czech Republic, guarantor).
Edition Diagnostics, Basel, MDPI, 2022, 2075-4418.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 30224 Radiology, nuclear medicine and medical imaging
Country of publisher Switzerland
Confidentiality degree is not subject to a state or trade secret
WWW URL
Impact factor Impact factor: 3.600
RIV identification code RIV/00216224:14110/22:00125484
Organization unit Faculty of Medicine
Doi http://dx.doi.org/10.3390/diagnostics12030612
UT WoS 000776880600001
Keywords in English computed tomography; catheter ablation; radiation
Tags 14110119, 14110513, podil, rivok
Tags International impact, Reviewed
Changed by Changed by: Mgr. Tereza Miškechová, učo 341652. Changed: 27/3/2023 13:25.
Abstract
(1) Background: Computer tomography (CT) is an imaging modality used in the pre-planning of radiofrequency catheter ablation (RFA) procedure in patients with cardiac arrhythmias. However, it is associated with a considerable ionizing radiation dose for patients. This study aims to develop and validate low-dose CT scanning protocols of the left atrium (LA) for RFA guidance. (2) Methods: 68 patients scheduled for RFA of atrial fibrillation were sequentially assigned to four groups of ECG-gated scanning protocols, based on the set tube current (TC): Group A (n = 20, TC = 33 mAs), Group B (n = 18, TC = 67 mAs), Group C (n = 10, TC = 135 mAs), and control Group D (n = 20, TC = 600 mAs). We used a 256-row multidetector CT with body weight-dependent tube voltage of 80 kVp (<70 kg), 100 kVp (70–90 kg), and 120 kVp (>90 kg). We evaluated scanning parameters including radiation dose, total scanning procedure time and signal-to-noise ratio (SNR). (3) Results: The average effective radiation dose (ED) was lower in Group A in comparison to Group B, C and D (0.83 (0.76–1.10), 1.55 (1.36–1.67), 2.91 (2.32–2.96) and 9.35 (8.00–10.04) mSv, p < 0.05). The total amount of contrast media was not significantly different between groups. The mean SNR was 6.5 (5.8–7.3), 7.1 (5.7–8.2), 10.8 (10.1–11.3), and 12.2 (9.9–15.7) for Group A, B, C and D, respectively. The comparisons of SNR in group A vs. B and C vs. D were without significant differences. (4) Conclusions: Optimized pre-ablation CT scanning protocols of the LA can reduce an average ED by 88.7%. Three dimensional (3D) models created with the lowest radiation protocol are useful for the integration of electro-anatomic-guided RFA procedures.
Links
MUNI/A/1462/2021, interní kód MUName: Nové zobrazovací, výpočetní a analytické metody v diagnostice a monitoraci kardiovaskulárních onemocnění
Investor: Masaryk University