ROHAN, Tomáš, Tomáš ANDRAŠINA, Peter MATKULČÍK, Vladan BERNARD and Vlastimil VÁLEK. Percutaneous Endoluminal Radiofrequency Ablation of Occluded Biliary Metal Stent in Malignancy Using Monopolar Technique: A Feasibility Study. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY. NEW YORK: SPRINGER, 2022, vol. 45, No 6, p. 873-878. ISSN 0174-1551. Available from: https://dx.doi.org/10.1007/s00270-022-03097-z.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Percutaneous Endoluminal Radiofrequency Ablation of Occluded Biliary Metal Stent in Malignancy Using Monopolar Technique: A Feasibility Study
Authors ROHAN, Tomáš (203 Czech Republic, guarantor, belonging to the institution), Tomáš ANDRAŠINA (703 Slovakia, belonging to the institution), Peter MATKULČÍK (703 Slovakia, belonging to the institution), Vladan BERNARD (203 Czech Republic, belonging to the institution) and Vlastimil VÁLEK (203 Czech Republic, belonging to the institution).
Edition CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, NEW YORK, SPRINGER, 2022, 0174-1551.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 30224 Radiology, nuclear medicine and medical imaging
Country of publisher Switzerland
Confidentiality degree is not subject to a state or trade secret
WWW URL
Impact factor Impact factor: 2.900
RIV identification code RIV/00216224:14110/22:00125706
Organization unit Faculty of Medicine
Doi http://dx.doi.org/10.1007/s00270-022-03097-z
UT WoS 000761841200001
Keywords in English Biliary malignancy; Biliary stenosis; Intraductal ablation; Metal stent; Monopolar technique; Radiofrequency ablation
Tags 14110216, 14110511, rivok
Tags International impact, Reviewed
Changed by Changed by: Mgr. Tereza Miškechová, učo 341652. Changed: 20/1/2023 10:46.
Abstract
Purpose: To prove feasibility and safety of percutaneous endoluminal radiofrequency ablation (eRFA) using a monopolar approach in treatment of occluded biliary stent in malignancy. Materials and Methods: The study included 11 patients with occluded biliary metal stent that had been implanted due to malignant biliary obstruction. All underwent metal stent recanalization by percutaneous eRFA in monopolar setting. Sixteen eRFA procedures were performed under fluoroscopic guidance with an EndoHPB 8F radiofrequency ablation catheter. The effect of stent recanalization was assessed based upon change from pre- to post-procedural diameter of the patent lumen of the metal stent (Wilcoxon test), primary and secondary stent patency (compared by log-rank test), catheter-free period, and overall survival. Adverse events were evaluated according to Common Terminology Criteria for Adverse Events (CTCEA) 4.0. Results: Recanalization of the metal stent by monopolar radiofrequency ablation was successful in all 11 patients. Diameter of the patent lumen of the stent significantly widened after the eRFA inside the stent (median 2 vs. 7 mm, p = 0.003). Grade 1 complications were observed in one-third of procedures. Median stent patency after recanalization by eRFA was non-inferior to primary metal stent patency (154 vs. 161 days, p = 0.27). Median catheter-free survival and overall survival after stent recanalization were 149 and 210 days, respectively. Conclusion: Endoluminal radiofrequency ablation in monopolar setting was shown to be a feasible and safe method for recanalization of occluded biliary metal stents.