HRDLIČKA, Aleš, Jitka HEGROVÁ, Jana HORSKÁ, David PROCHAZKA, Jakub BUDAY, Martina BUCKOVÁ, Markéta HOLÁ, Pavel POŘÍZKA, Karel NOVOTNÝ, Jozef KAISER and Viktor KANICKÝ. Laser-induced breakdown spectroscopy in analysis of algae contamination on the filter. In European Symposium on Analytical Spectrometry ESAS 2022 - 17th Czech - Slovak Spectroscopic Conference. 2022.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Laser-induced breakdown spectroscopy in analysis of algae contamination on the filter
Authors HRDLIČKA, Aleš (203 Czech Republic, belonging to the institution), Jitka HEGROVÁ (203 Czech Republic), Jana HORSKÁ (203 Czech Republic, belonging to the institution), David PROCHAZKA (203 Czech Republic), Jakub BUDAY (703 Slovakia), Martina BUCKOVÁ (203 Czech Republic), Markéta HOLÁ (203 Czech Republic, belonging to the institution), Pavel POŘÍZKA (203 Czech Republic), Karel NOVOTNÝ (203 Czech Republic, belonging to the institution), Jozef KAISER (203 Czech Republic) and Viktor KANICKÝ (203 Czech Republic, belonging to the institution).
Edition European Symposium on Analytical Spectrometry ESAS 2022 - 17th Czech - Slovak Spectroscopic Conference, 2022.
Other information
Original language English
Type of outcome Conference abstract
Field of Study 10406 Analytical chemistry
Country of publisher Czech Republic
Confidentiality degree is not subject to a state or trade secret
WWW odkaz na konferenční stránky
RIV identification code RIV/00216224:14310/22:00126686
Organization unit Faculty of Science
Keywords (in Czech) spektroskopie laserem buzeného plazmatu (LIBS); analýza; řasy; kontaminace; stínové zobrazení
Keywords in English laser-induced breakdown spectroscopy; analysis; algae; contamination; shadowgraphy
Tags International impact
Changed by Changed by: Mgr. Aleš Hrdlička, Ph.D., učo 22863. Changed: 23/9/2022 09:39.
Abstract
The heavy metal contamination of algae on a filter was directly monitored with laser-induced breakdown spectroscopy (LIBS) as a demonstration of LIBS capabilities. To enhance the LIBS sensitivity, single or double pulse arrangements employing 1064 and 532 nm lasers, noble gasses or nanoparticles were tested. Liquid samples of the green alga Desmodesmus subspicatus were intentionally contaminated with chromium, nickel or zinc, incubated, filtered, and the filters with the algae were analysed. Also laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for comparison and (ICP-MS) was used as a reference method. One half of the filter with the algae was dissolved and analysed as a solution with ICP-MS and the second half was subjected to the LIBS and LA-ICP-MS analysis. The metals were attributable to the algae contamination and detectable with LIBS. The results from the LIBS provided almost equivalent information about the relative changes of the contaminants concentration in the algae. The LIBS sensitivity with a Czerny-Turner spectrometer was fully comparable with the ICP-MS procedure. The LIBS trends were more similar to the LA-ICP-MS ones. The algae growth inhibition in dependence on the contaminant content, number of cells and the rate of cell contamination can be alternatively monitored with LIBS instead of the complicated procedure in ICP-MS analysis.