J 2022

Influence of Label and Solid Support on the Performance of Heterogeneous Immunoassays

MAKHNEVA, Ekaterina; Dorota SKLENÁROVÁ; Julian BRANDMEIER; Antonín HLAVÁČEK; Hans-Heiner GORRIS et. al.

Základní údaje

Originální název

Influence of Label and Solid Support on the Performance of Heterogeneous Immunoassays

Autoři

MAKHNEVA, Ekaterina (643 Rusko, domácí); Dorota SKLENÁROVÁ (703 Slovensko, domácí); Julian BRANDMEIER (276 Německo, domácí); Antonín HLAVÁČEK (203 Česká republika); Hans-Heiner GORRIS (276 Německo, domácí); Petr SKLÁDAL (203 Česká republika, domácí) a Zdeněk FARKA (203 Česká republika, garant, domácí)

Vydání

Analytical Chemistry, Washington, DC, American Chemical Society, 2022, 0003-2700

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10406 Analytical chemistry

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 7.400

Kód RIV

RIV/00216224:14310/22:00127321

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000889895000001

EID Scopus

2-s2.0-85142460861

Klíčová slova anglicky

Immunoassay; Magnetic preconcentration; Photon-upconversion nanoparticle; Prostate-specific antigen

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 24. 10. 2024 11:16, Mgr. Adéla Pešková

Anotace

V originále

Conventional immunochemical methods used in clinical analysis are often not sensitive enough for early-stage diagnosis, resulting in the need for novel assay formats. Here, we provide a detailed comparison of the effect of different labels and solid supports on the performance of heterogeneous immunoassays. When comparing three types of streptavidin-modified labels─horseradish peroxidase, carboxyfluorescein, and photon-upconversion nanoparticles (UCNPs)─UCNPs led to the most sensitive and robust detection of the cancer biomarker prostate-specific antigen. Additionally, we compared the immunoassay formats based on conventional microtiter plates and magnetic microbeads (MBs). In both cases, the highest signal-to-background ratios and the lowest limits of detection (LODs) were obtained by using the UCNP labels. The MB-based upconversion-linked immunosorbent assay carried out with a preconcentration step provided the lowest LOD of 0.46 pg/mL in serum. The results demonstrate that the use of UCNPs and MBs can significantly improve the sensitivity and working range of heterogeneous immunoassays for biomarker detection.

Návaznosti

EF18_053/0016952, projekt VaV
Název: Postdoc2MUNI
GA21-03156S, projekt VaV
Název: Foton-upkonverzní značky pro mikrofluidní jednomolekulové imunostanovení proteinových biomarkerů
Investor: Grantová agentura ČR, Foton-upkonverzní značky pro mikrofluidní jednomolekulové imunostanovení proteinových biomarkerů
90127, velká výzkumná infrastruktura
Název: CIISB II