J 2022

Feasibility of Mouth-to-Mouth Ventilation through FFP2 Respirator in BLS Training during COVID-19 Pandemic (MOVERESP Study): Simulation-Based Study

KOSINOVÁ, Martina, Petr ŠTOURAČ, Tereza PROKOPOVÁ, Tereza VAFKOVÁ, Václav VAFEK et. al.

Basic information

Original name

Feasibility of Mouth-to-Mouth Ventilation through FFP2 Respirator in BLS Training during COVID-19 Pandemic (MOVERESP Study): Simulation-Based Study

Name in Czech

Možnost ventilace z úst do úst přes FFP2 respiráto v BLS tréninku v průběhů COVID-19 pandemie (MOVEREPS studie): simulační studie

Authors

KOSINOVÁ, Martina (203 Czech Republic, belonging to the institution), Petr ŠTOURAČ (203 Czech Republic, guarantor, belonging to the institution), Tereza PROKOPOVÁ (203 Czech Republic, belonging to the institution), Tereza VAFKOVÁ (203 Czech Republic, belonging to the institution), Václav VAFEK (203 Czech Republic, belonging to the institution), Daniel BARVÍK (203 Czech Republic, belonging to the institution), Tamara SKŘÍŠOVSKÁ (203 Czech Republic, belonging to the institution), Jan DVOŘÁČEK (203 Czech Republic, belonging to the institution), Jana DJAKOW (203 Czech Republic, belonging to the institution), Jozef KLUČKA (703 Slovakia, belonging to the institution), Jiří JARKOVSKÝ (203 Czech Republic, belonging to the institution) and Pavel PLEVKA (203 Czech Republic, belonging to the institution)

Edition

Children-Basel, BASEL, SWITZERLAND, MDPI, 2022, 2227-9067

Other information

Language

English

Type of outcome

Článek v odborném periodiku

Field of Study

30221 Critical care medicine and Emergency medicine

Country of publisher

Switzerland

Confidentiality degree

není předmětem státního či obchodního tajemství

References:

Impact factor

Impact factor: 2.400

RIV identification code

RIV/00216224:14110/22:00127628

Organization unit

Faculty of Medicine

UT WoS

000894737500001

Keywords (in Czech)

resuscitace; dýchání z úst do úst; neodkladná pomoc; COVID-19; trénink

Keywords in English

resuscitation; mouth-to-mouth breathing; life support; COVID-19; training

Tags

International impact, Reviewed
Změněno: 14/3/2023 08:42, Mgr. Tereza Miškechová

Abstract

V originále

Background: Due to the COVID-19 pandemic, Basic Life Support (BLS) training has been limited to compression-only or bag-mask ventilation. The most breathable nanofiber respirators carry the technical possibility for inflation of the mannequin. The aim of this study was to assess the efficacy of mouth-to-mouth breathing through a FFP2 respirator during BLS. Methods: In the cross-over simulation-based study, the medical students performed BLS using a breathable nanofiber respirator for 2 min on three mannequins. The quantitative and qualitative efficacy of mouth-to-mouth ventilation through the respirator in BLS training was analyzed. The primary aim was the effectivity of mouth-to-mouth ventilation through a breathable respirator. The secondary aims were mean pause, longest pause, success in achieving the optimal breath volume, technique of ventilation, and incidence of adverse events. Results: In 104 students, effective breath was reached in 951 of 981 (96.9%) attempts in Adult BLS mannequin (Prestan), 822 of 906 (90.7%) in Resusci Anne, and 1777 of 1857 (95.7%) in Resusci Baby. In Resusci Anne and Resusci Baby, 28.9%/15.9% of visible chest rises were evaluated as low-, 33.0%/44.0% as optimal-, and 28.8%/35.8% as high-volume breaths. Conclusions: Mouth-to-mouth ventilation through a breathable respirator had an effectivity greater than 90%.

In Czech

Souvislosti: Kvůli pandemii COVID-19 se školení Basic Life Support (BLS) omezilo pouze na kompresní ventilaci nebo ventilaci s vakovou maskou. Nejprodyšnější nanovlákenné respirátory nesou technickou možnost nafouknutí figuríny. Cílem této studie bylo posoudit účinnost dýchání z úst do úst přes respirátor FFP2 během BLS. Metody: Ve studii založené na zkřížené simulaci prováděli studenti medicíny BLS pomocí dýchatelného nanovlákenného respirátoru po dobu 2 minut na třech figurínách. Byla analyzována kvantitativní a kvalitativní účinnost ventilace z úst do úst přes respirátor v tréninku BLS. Primárním cílem byla efektivita ventilace z úst do úst přes prodyšný respirátor. Sekundárními cíli byla průměrná pauza, nejdelší pauza, úspěšnost dosažení optimálního dechového objemu, technika ventilace a výskyt nežádoucích příhod. Výsledky: U 104 studentů bylo dosaženo efektivního dechu v 951 z 981 (96,9 %) pokusů u Adult BLS manekýn (Prestan), 822 z 906 (90,7 %) u Resusci Anne a 1777 z 1857 (95,7 %) u Resusci Baby. U Resusci Anne a Resusci Baby bylo 28,9 %/15,9 % viditelných zvedání hrudníku hodnoceno jako nízké, 33,0 %/44,0 % jako optimální a 28,8 %/35,8 % jako vysokoobjemové dechy. Závěry: Ventilace z úst do úst pomocí dýchacího respirátoru měla účinnost vyšší než 90 %.

Links

MUNI/A/1166/2021, interní kód MU
Name: Protektivní plicní ventilace během celkové anestezie a intenzivní péče u pediatrických pacientů: retrospektivní studie III (Acronym: TIVAC 3)
Investor: Masaryk University
MUNI/A/1178/2021, interní kód MU
Name: Simulační trénink v identifikaci a prevenci kritických událostí v anesteziologii a intenzivní medicíně III. (Acronym: SIMUCRITICAL)
Investor: Masaryk University