J 2023

Possibilities of Interpreting the Night-to-Day Ratio Specified by 24-Hour Blood Pressure Monitoring

HAVELKOVÁ, Alena, Petr DVORAK, Jarmila SIEGELOVÁ, Petr DOBŠÁK, Petr FILIPENSKY et. al.

Základní údaje

Originální název

Possibilities of Interpreting the Night-to-Day Ratio Specified by 24-Hour Blood Pressure Monitoring

Autoři

HAVELKOVÁ, Alena (203 Česká republika, garant, domácí), Petr DVORAK (203 Česká republika), Jarmila SIEGELOVÁ (203 Česká republika, domácí), Petr DOBŠÁK (203 Česká republika, domácí), Petr FILIPENSKY (203 Česká republika) a Germaine CORNELISSEN (840 Spojené státy)

Vydání

International Journal of Clinical Practice, LONDON, WILEY-HINDAWI, 2023, 1368-5031

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30218 General and internal medicine

Stát vydavatele

Velká Británie a Severní Irsko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

URL

Impakt faktor

Impact factor: 2.600 v roce 2022

Kód RIV

RIV/00216224:14110/23:00130346

Organizační jednotka

Lékařská fakulta

DOI

http://dx.doi.org/10.1155/2023/6530295

UT WoS

000935553300002

Klíčová slova anglicky

Blood Pressure Monitoring; Night-to-Day Ratio

Štítky

14110614, rivok

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 26. 7. 2023 10:52, Mgr. Tereza Miškechová

Anotace

V originále

Aim. Specify the risk rate of incorrect patient classification based on the night-to-day ratio specification from singular 24-h ABPM in comparison to the results of 7-day ABPM monitoring Materials and Methods. 1197 24 h cycles were enrolled in 171 subjects in the study and divided into 4 groups: group 1 (40 healthy men and women without exercise), group 2 (40 healthy exercise-training men and women), group 3 (40 patients with ischemic coronary artery disease without exercise), and group 4 (51 patients with ischemic coronary artery disease following cardiovascular rehabilitation). The subject of the evaluation was the percentage rate of incorrect subject classification (dipper, nondipper, extreme dipper, and riser) based on the mean blood pressure values for 7 days and from seven independent 24-hour cycles (the mean value mode). Results. In the case of the individuals included in the monitored groups, the mean night-to-day ratio-based (mode for the 7 days versus the individual days of 24-hour monitoring) classification accordance ranged between 59% and 62%. Only in singular cases did the accordance reach 0% or 100%. The accordance size was not dependent on the health or cardiovascular disease (; 56% vs. 54%) or physical activity (; 55% vs. 54%) of the monitored individuals. Conclusion. The specification of the night-to-day ratio of each individual for each day of the 7-day ABPM monitoring would be the most convenient option. In many patients, diagnosing could thus be based on the most frequently occurring values (mode specification). The study protocol was registered with ClinicalTrials.gov (NCT05264090).

Návaznosti

LM2023049, projekt VaV
Název: Český národní uzel Evropské sítě infrastruktur klinického výzkumu
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CZECRIN - Czech National Node to the European Clinical Research Infrastructure Network
Zobrazeno: 3. 11. 2024 08:17