EMMER, Jan, Tomáš TOMÁŠ, Vasileios APOSTOLOPOULOS, Pavel BRANČÍK, Jakub RAPI and Luboš NACHTNEBL. Mechanical complications and infection control comparison of custom-made and prefabricated articular hip spacers in the treatment of periprosthetic infection. JOINT DISEASES AND RELATED SURGERY. ANKARA: TURKISH JOINT DISEASES FOUNDATION, 2023, vol. 34, No 3, p. 557-564. ISSN 2687-4792. Available from: https://dx.doi.org/10.52312/jdrs.2023.1155.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Mechanical complications and infection control comparison of custom-made and prefabricated articular hip spacers in the treatment of periprosthetic infection
Authors EMMER, Jan (203 Czech Republic, belonging to the institution), Tomáš TOMÁŠ (203 Czech Republic, belonging to the institution), Vasileios APOSTOLOPOULOS (203 Czech Republic, belonging to the institution), Pavel BRANČÍK (203 Czech Republic, belonging to the institution), Jakub RAPI (203 Czech Republic, belonging to the institution) and Luboš NACHTNEBL (203 Czech Republic, guarantor, belonging to the institution).
Edition JOINT DISEASES AND RELATED SURGERY, ANKARA, TURKISH JOINT DISEASES FOUNDATION, 2023, 2687-4792.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 30211 Orthopaedics
Country of publisher Czech Republic
Confidentiality degree is not subject to a state or trade secret
WWW URL
Impact factor Impact factor: 1.600 in 2022
RIV identification code RIV/00216224:14110/23:00132590
Organization unit Faculty of Medicine
Doi http://dx.doi.org/10.52312/jdrs.2023.1155
UT WoS 001055515900001
Keywords in English Custom-made articular hip spacer; periprosthetic joint infection; prefabricated hip spacer
Tags 14110123, rivok
Tags International impact, Reviewed
Changed by Changed by: Mgr. Michal Petr, učo 65024. Changed: 8/7/2024 14:00.
Abstract
Objectives: The purpose of our study was to compare the complication rate and the outcomes of custom-made spacers (C-spacers) and prefabricated articular spacers ( P-spacers) in the treatment of periprosthetic infection. Patients and methods: In this retrospective study, 78 patients (44 females, 34 males; mean age: 68.5 +/- 9.48 years; range, 47 to 82 years) with articular spacers implanted in our institution were analyzed between January 2009 and December 2019. We recorded implant results as per mechanical complications, infection control, the interval from surgery to definitive hip replacement, and the rate of achieving recovery of joint function after stage two arthroplasty. Results: There were 29 revised spacers; 18 of them were C-spacers and 11 were P-spacers (p= 0.0383). A total of 16 dislocations were recorded, of which six were dislocations of C-spacers, and 10 were dislocations of P- spacers (p= 0.0082). Additionally, we registered four spacer breakages, all of which occurred in C-spacers (p= 0.295). C-spacers failed early, at an mean interval of 2.2 weeks after implantation, and P- spacers failed later, with an mean of 9.3 weeks after implantation (p=0.0187). A total of nine reinfection complications of spacers were registered; only one infection of P-spacers, and eight infections related to C-spacers ( p= 0.2583). Definitive revision total hip arthroplasty (rTHA) after spacer explantation and successful treatment of the infection occurred in 63 cases out of 78 patients. Definitive rTHA occurred after the use of C-spacers in 41 (78%) patients and after the use of C- spacers in 22 (84%) patients (p=0.7816). C-spacers had a mean interval from spacer implantation to definitive rTHA of 6.56 +/- 6.03 months, and P-spacers had a mean interval of 4 +/- 1.93 months (p= 0.0164). Conclusion: Custom-made spacers were shown to have lower mechanical complication rates than prefabricated ones but more infection complications. Prefabricated spacers had more dislocations and fewer breakages. Custom-made spacer mechanical failures occurred earlier compared to prefabricated ones.
PrintDisplayed: 20/7/2024 23:29