Detailed Information on Publication Record
2023
Validity and reliability of automated treadmill six-minute walk test in patients entering exercise-based cardiac rehabilitation
NEVELIKOVA, Marketa, Filip DOSBABA, Garyfallia PEPERA, Marián FELŠŐCI, Katerina BATALIKOVA et. al.Basic information
Original name
Validity and reliability of automated treadmill six-minute walk test in patients entering exercise-based cardiac rehabilitation
Authors
NEVELIKOVA, Marketa (203 Czech Republic), Filip DOSBABA (203 Czech Republic, belonging to the institution), Garyfallia PEPERA (300 Greece), Marián FELŠŐCI (703 Slovakia), Katerina BATALIKOVA (203 Czech Republic), Jing Jing SU (156 China) and Ladislav BAŤALÍK (203 Czech Republic, guarantor, belonging to the institution)
Edition
Annals of Medicine, ABINGDON, TAYLOR & FRANCIS LTD, 2023, 0785-3890
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
30217 Urology and nephrology
Country of publisher
United Kingdom of Great Britain and Northern Ireland
Confidentiality degree
není předmětem státního či obchodního tajemství
References:
Impact factor
Impact factor: 4.400 in 2022
RIV identification code
RIV/00216224:14110/23:00133342
Organization unit
Faculty of Medicine
UT WoS
001144285600001
Keywords in English
Six minute walk test; cardiac rehabilitation; automatized treadmill; functional capacity; technology-assisted assessment
Tags
International impact, Reviewed
Změněno: 31/1/2024 10:29, Mgr. Tereza Miškechová
Abstract
V originále
Introduction: The six-minute walk test (6MWT) is a well-established tool for assessing submaximal functional capacity for cardiac patients, but space limitations challenge its implementation. Treadmill-based (TR) 6MWT is a promising alternative, but it requires patients to complete a familiarization test to adapt treadmill speed regulation. With the advancement of sensors, it is possible to automatically control speed for individual patients and thus overcome the space limitation or the speed control difficulty on the treadmill for each patient.Methods: This study investigated the validity and interchangeability of automated speed TR6MWT and standard hallway (HL) 6MWT. Eighteen patients were assessed at baseline of the 12-week cardiac rehabilitation program. Fourteen of them were assessed after rehabilitation. All patients performed three TR6MWTs and three HL6MWTs at baseline and one of each test after the program.Results: Patients well tolerated the TR6MWT. There was a strong correlation between both test methods (r = 0.79). However, patients performed significantly better in HL6MWT (514.8m +/- 59.7m) than in TR6MWT (447.2 +/- 79.1m) with 95% CI, 40.4-94.6m, p < 0.05. Both tests showed high test-retest reliability (intraclass correlation coefficient of 0.86). The TR6MWT showed a valuable comparison of the effect of the cardiac rehabilitation program (20% increase, effect size 1.1) even though it is not interchangeable with the HL6MWT.Conclusion: The automated speed TR6MWT appears to be an acceptable tool with adequate validity, reliability, and responsiveness for assessing functional capacity in patients utilizing cardiac rehabilitation programs.