HNATKOVA, Katerina, Irena ANDRŠOVÁ, Tomáš NOVOTNÝ, Bert VANDERBERK, David SPRENKELER, Juhani JUNTTILA, Tobias REICHLIN, Simon SCHLOEGL, Marc A VOS, Tim FRIEDE, Axel BAUER, Heikki V HUIKURI, Rik WILLEMS, Georg SCHMIDT, Christian STICHERLING, Markus ZABEL and Marek MALÍK. QRS complex and T wave planarity for the efficacy prediction of automatic implantable defibrillators. Heart. London: BMJ Publishing Group, 2024, vol. 110, No 3, p. 178-187. ISSN 1355-6037. Available from: https://dx.doi.org/10.1136/heartjnl-2023-322878.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name QRS complex and T wave planarity for the efficacy prediction of automatic implantable defibrillators
Authors HNATKOVA, Katerina (203 Czech Republic), Irena ANDRŠOVÁ (203 Czech Republic, belonging to the institution), Tomáš NOVOTNÝ (203 Czech Republic, belonging to the institution), Bert VANDERBERK, David SPRENKELER, Juhani JUNTTILA, Tobias REICHLIN, Simon SCHLOEGL, Marc A VOS, Tim FRIEDE, Axel BAUER, Heikki V HUIKURI, Rik WILLEMS, Georg SCHMIDT, Christian STICHERLING, Markus ZABEL and Marek MALÍK (203 Czech Republic, belonging to the institution).
Edition Heart, London, BMJ Publishing Group, 2024, 1355-6037.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 30201 Cardiac and Cardiovascular systems
Country of publisher United Kingdom of Great Britain and Northern Ireland
Confidentiality degree is not subject to a state or trade secret
WWW URL
Impact factor Impact factor: 5.700 in 2022
Organization unit Faculty of Medicine
Doi http://dx.doi.org/10.1136/heartjnl-2023-322878
UT WoS 001070694100001
Keywords in English Defibrillators; Implantable; Biomarkers; Electrocardiography
Tags 14110211, rivok
Tags International impact, Reviewed
Changed by Changed by: Mgr. Tereza Miškechová, učo 341652. Changed: 14/2/2024 09:15.
Abstract
Objective To test the hypothesis that in recipients of primary prophylactic implantable cardioverter-defibrillators (ICDs), the non-planarity of ECG vector loops predicts (a) deaths despite ICD protection and (b) appropriate ICD shocks.Methods Digital pre-implant ECGs were collected in 1948 ICD recipients: 21.4% females, median age 65 years, 61.5% ischaemic heart disease (IHD). QRS and T wave three-dimensional loops were constructed using singular value decomposition that allowed to measure the vector loop planarity. The non-planarity, that is, the twist of the three-dimensional loops out of a single plane, was related to all-cause mortality (n=294; 15.3% females; 68.7% IHD) and appropriate ICD shocks (n=162; 10.5% females; 87.7% IHD) during 5-year follow-up after device implantation. Using multivariable Cox regression, the predictive power of QRS and T wave non-planarity was compared with that of age, heart rate, left ventricular ejection fraction, QRS duration, spatial QRS-T angle, QTc interval and T-peak to T-end interval.Results QRS non-planarity was significantly (p<0.001) associated with follow-up deaths despite ICD protection with HR of 1.339 (95% CI 1.165 to 1.540) but was only univariably associated with appropriate ICD shocks. Non-planarity of the T wave loop was the only ECG-derived index significantly (p<0.001) associated with appropriate ICD shocks with multivariable Cox regression HR of 1.364 (1.180 to 1.576) but was not associated with follow-up mortality.Conclusions The analysed data suggest that QRS and T wave non-planarity might offer distinction between patients who are at greater risk of death despite ICD protection and those who are likely to use the defibrillator protection.
Links
MUNI/A/1412/2022, interní kód MUName: Nevyřešené otázky a nové metody hodnocení elektrokardiografického signálu a struktur myokardu
Investor: Masaryk University
PrintDisplayed: 20/7/2024 12:14