Detailed Information on Publication Record
2024
QRS complex and T wave planarity for the efficacy prediction of automatic implantable defibrillators
HNATKOVA, Katerina, Irena ANDRŠOVÁ, Tomáš NOVOTNÝ, Bert VANDERBERK, David SPRENKELER et. al.Basic information
Original name
QRS complex and T wave planarity for the efficacy prediction of automatic implantable defibrillators
Authors
HNATKOVA, Katerina (203 Czech Republic), Irena ANDRŠOVÁ (203 Czech Republic, belonging to the institution), Tomáš NOVOTNÝ (203 Czech Republic, belonging to the institution), Bert VANDERBERK, David SPRENKELER, Juhani JUNTTILA, Tobias REICHLIN, Simon SCHLOEGL, Marc A VOS, Tim FRIEDE, Axel BAUER, Heikki V HUIKURI, Rik WILLEMS, Georg SCHMIDT, Christian STICHERLING, Markus ZABEL and Marek MALÍK (203 Czech Republic, belonging to the institution)
Edition
Heart, London, BMJ Publishing Group, 2024, 1355-6037
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
30201 Cardiac and Cardiovascular systems
Country of publisher
United Kingdom of Great Britain and Northern Ireland
Confidentiality degree
není předmětem státního či obchodního tajemství
References:
Impact factor
Impact factor: 5.700 in 2022
Organization unit
Faculty of Medicine
UT WoS
001070694100001
Keywords in English
Defibrillators; Implantable; Biomarkers; Electrocardiography
Tags
International impact, Reviewed
Změněno: 14/2/2024 09:15, Mgr. Tereza Miškechová
Abstract
V originále
Objective To test the hypothesis that in recipients of primary prophylactic implantable cardioverter-defibrillators (ICDs), the non-planarity of ECG vector loops predicts (a) deaths despite ICD protection and (b) appropriate ICD shocks.Methods Digital pre-implant ECGs were collected in 1948 ICD recipients: 21.4% females, median age 65 years, 61.5% ischaemic heart disease (IHD). QRS and T wave three-dimensional loops were constructed using singular value decomposition that allowed to measure the vector loop planarity. The non-planarity, that is, the twist of the three-dimensional loops out of a single plane, was related to all-cause mortality (n=294; 15.3% females; 68.7% IHD) and appropriate ICD shocks (n=162; 10.5% females; 87.7% IHD) during 5-year follow-up after device implantation. Using multivariable Cox regression, the predictive power of QRS and T wave non-planarity was compared with that of age, heart rate, left ventricular ejection fraction, QRS duration, spatial QRS-T angle, QTc interval and T-peak to T-end interval.Results QRS non-planarity was significantly (p<0.001) associated with follow-up deaths despite ICD protection with HR of 1.339 (95% CI 1.165 to 1.540) but was only univariably associated with appropriate ICD shocks. Non-planarity of the T wave loop was the only ECG-derived index significantly (p<0.001) associated with appropriate ICD shocks with multivariable Cox regression HR of 1.364 (1.180 to 1.576) but was not associated with follow-up mortality.Conclusions The analysed data suggest that QRS and T wave non-planarity might offer distinction between patients who are at greater risk of death despite ICD protection and those who are likely to use the defibrillator protection.
Links
MUNI/A/1412/2022, interní kód MU |
|