J 2024

Comparison of the reverse scan technique with an intraoral scanner and the traditional impression technique

HYŠPLER, Pavel, Petra URBANOVÁ and Taťjana DOSTÁLOVÁ

Basic information

Original name

Comparison of the reverse scan technique with an intraoral scanner and the traditional impression technique

Authors

HYŠPLER, Pavel, Petra URBANOVÁ and Taťjana DOSTÁLOVÁ

Edition

Journal of Prosthetic Dentistry, Elsevier Inc. 2024, 0022-3913

Other information

Language

English

Type of outcome

Article in a journal

Country of publisher

United States of America

Confidentiality degree

is not subject to a state or trade secret

References:

Impact factor

Impact factor: 4.300 in 2023

Organization unit

Faculty of Science

Tags

International impact, Reviewed
Changed: 17/3/2025 11:05, Mgr. Marie Novosadová Šípková, DiS.

Abstract

V originále

Statement of problem Intraoral scanners have many advantages but have limited applicability for extensive tooth-supported or implant-supported prostheses because of merging errors. Purpose The purpose of this study was to compare the reverse scan technique (RST) with an intraoral scanner using the traditional impression technique both in vitro and in vivo. Material and methods A participant was scanned 10 times with an intraoral scanner. Then, the RST was performed 3 times in the oral cavity. One of the intraoral scans was chosen to make a 3-dimensionally (3D) printed cast. The printed cast was scanned 10 times with a laboratory scanner (Control cast) and 10 times with an intraoral scanner (IOS cast). The RST was performed 10 times (RST cast), and 10 dental impressions were made using the traditional splinted technique on the same cast (Impression cast). A laboratory scanner was used to obtain standard tessellation language (STL) files of the tested methods. A newly developed pyramid replacement method was used to evaluate accuracy. This method uses modified virtual abutments with integrated pyramids that determine the exact measurement points. The obtained data were processed using Procrustes analysis and statistically analyzed (α=.05). Results The Procrustes distances were Control cast 0 to 0.4 µm (median 0.3 µm), RST cast 5.6 to 6.9 µm (median 6.2 µm), Impression cast 5.4 to 7.1 µm (median 6.5 µm), and IOS cast group 4.5 to 41.2 µm (median 5.8 µm). In the participant, the Procrustes distance values were RST intraoral 9.5 to 9.6 µm (median 9.5 µm) and IOS intraoral 5.7 to 18.3 µm (median 10.9 µm). Conclusions The reverse scan technique is an acceptable fully digital replacement for traditional impression making. Using an IOS to obtain a 3D cast of an implant-supported interim prosthesis with scannable implant analogs is not recommended. It is more beneficial to use laboratory scanners rather than intraoral scanners for the digitization of precision improvement devices such as bonded interim implant-supported prostheses with a scannable implant analog or solid index.

Links

MUNI/A/1597/2023, interní kód MU
Name: Rozvoj automatizace při zpracování obrazových dat ve forenzní a aplikované antropologii
Investor: Masaryk University, Automated Image Processing in Forensic and Applied Anthropology