GLATZ, Zdeněk, Jiřina POSPÍŠILOVÁ and Pavel MUSIL. Determination of Gentiopicroside in Extracts of Centaurium erythreae and Gentiana lutea by Micellar Electrokinetic Capillary Chromatography. J.Liquid Chromatogr. Rel. Technol. New York: Marcel Dekker, 2000, vol. 23, No 12, p. 1831-1839. ISSN 1082-6076.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Determination of Gentiopicroside in Extracts of Centaurium erythreae and Gentiana lutea by Micellar Electrokinetic Capillary Chromatography
Authors GLATZ, Zdeněk, Jiřina POSPÍŠILOVÁ and Pavel MUSIL.
Edition J.Liquid Chromatogr. Rel. Technol. New York, Marcel Dekker, 2000, 1082-6076.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10600 1.6 Biological sciences
Country of publisher United States of America
Confidentiality degree is not subject to a state or trade secret
Impact factor Impact factor: 0.844
RIV identification code RIV/00216224:14310/00:00003302
Organization unit Faculty of Science
UT WoS 000088408400004
Keywords in English micellar electrokinetic chromatography; gentiopicroside; gentiana; centaurium
Tags centaurium, gentiana, Gentiopicroside, Micellar Electrokinetic Chromatography
Changed by Changed by: prof. RNDr. Zdeněk Glatz, CSc., učo 1865. Changed: 27/2/2001 10:58.
Abstract
Micellar electrokinetic capillary chromatography has been developed as a promising method for the determination of gentiopicroside. The separation conditions have been optimised with respect to the different parameters including SDS concentration, pH and ion strength of the background electrolyte, and temperature of capillary. A buffer consisting of 100 mM SDS in 20 mM sodium dihydrogen phosphate, 20 mM disodium tetraborate pH 8.6 was found to be the most suitable electrolyte for this separation. The applied voltage of 28 kV (positive polarity) and the temperature of capillary 20 oC gave the best separation of secoiridiods. The linear detection range for concentration versus peak area for the assay is from 5 to 500 mg . ml-1 (correlation coefficient 0.9998) with a detection limit of 0.3 mg . ml-1. The inter-day reproducibility of the peak area was 2.5 % and the inter-day reproducibility of the migration time was below 0.16 %. The developed method was successfully used to quantify gentiopicroside in extracts of the overground parts of Centaurium erythreae and the roots of Gentiana lutea, and in the liqueur Becherovka. The results were in good agreement with those determined by HPLC.
Links
GA303/00/D062, research and development projectName: Biologická dostupnost a mechanismus antioxidačního účinku fenolických kyselin a lignanů
Investor: Czech Science Foundation, Bioavailability and mechanism of antioxidant activity of phenolic acids and lignans
PrintDisplayed: 20/9/2024 11:33