KVASNIČKOVÁ, Leona, Zdeněk GLATZ, Vladislav KAHLE, Jiří SLANINA a Pavel MUSIL. Capillary Electrochromatography in Polyacrylamide Based Monolithic Capillary Columns. In Book of Abstract, International Symposium on Capillary Electrophoresis, ITP 2000. Bratislava: Slovenská chemická společnost, 2000, s. 85. |
Další formáty:
BibTeX
LaTeX
RIS
@inproceedings{331271, author = {Kvasničková, Leona and Glatz, Zdeněk and Kahle, Vladislav and Slanina, Jiří and Musil, Pavel}, address = {Bratislava}, booktitle = {Book of Abstract, International Symposium on Capillary Electrophoresis, ITP 2000}, keywords = {Capillary electrochromatography; Monolothic columns; Lignans; Schizandra}, language = {eng}, location = {Bratislava}, pages = {85-85}, publisher = {Slovenská chemická společnost}, title = {Capillary Electrochromatography in Polyacrylamide Based Monolithic Capillary Columns}, year = {2000} }
TY - JOUR ID - 331271 AU - Kvasničková, Leona - Glatz, Zdeněk - Kahle, Vladislav - Slanina, Jiří - Musil, Pavel PY - 2000 TI - Capillary Electrochromatography in Polyacrylamide Based Monolithic Capillary Columns PB - Slovenská chemická společnost CY - Bratislava KW - Capillary electrochromatography KW - Monolothic columns KW - Lignans KW - Schizandra N2 - Capillary electrochromatography (CEC) is a hybrid separation technique that combines the benefits of both capillary zone electrophoresis and high performance liquid chromatography. The high efficiency and resolution of CEC offers an alternative to pressure-driven chromatography systems. Polymer based monolithic capillary columns quickly become a well-established stationary phases in CEC as they eliminated the need of frits and packing procedures. The large variety of available chemistries make these columns an attractive alternative to columns packed with particulate materials. The macroporous polyacrylamide columns for CEC were prepared by in situ copolymerisation of acrylamide, bisacrylamide, vinylsulfonic acid and lauryl acrylate in presence of polyethylene glycol as a porogenic agent. The columns were successfully used to analyse and quantify lignans in extract of the seeds of Schisandra chinensis. Good separations were achieved in less than 20 min. The migration time and peak area reproducibilities were better than 4 %. The results were compared with those obtained by reverse-phase HPLC, the levels of schizandrin, gomisin A, gomisin N and wuweizisu C determined by CEC were in good agreement with those determined by HPLC. ER -
KVASNIČKOVÁ, Leona, Zdeněk GLATZ, Vladislav KAHLE, Jiří SLANINA a Pavel MUSIL. Capillary Electrochromatography in Polyacrylamide Based Monolithic Capillary Columns. In \textit{Book of Abstract, International Symposium on Capillary Electrophoresis, ITP 2000}. Bratislava: Slovenská chemická společnost, 2000, s.~85.
|