Informační systém MU
KANICKÝ, Viktor, Vítězslav OTRUBA, Karel NOVOTNÝ, Petr MUSIL a Jean-Michel MERMET. Calibration graphs for steels by IR laser ablation inductively coupled plasma atomic emission spectrometry. Fresenius Journal of Analytical Chemistry. Berlin: Springer-Verlag, roč. 370, č. 4, s. 387-392. ISSN 0937-0633. 2001.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Calibration graphs for steels by IR laser ablation inductively coupled plasma atomic emission spectrometry
Autoři KANICKÝ, Viktor (203 Česká republika, garant), Vítězslav OTRUBA (203 Česká republika), Karel NOVOTNÝ (203 Česká republika), Petr MUSIL (203 Česká republika) a Jean-Michel MERMET.
Vydání Fresenius Journal of Analytical Chemistry, Berlin, Springer-Verlag, 2001, 0937-0633.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 1.649
Kód RIV RIV/00216224:14310/01:00004314
Organizační jednotka Přírodovědecká fakulta
UT WoS 000170115100012
Klíčová slova anglicky Laser ablation; Infrared laser; Inductively coupled plasma; Atomic emission spectrometry; Steel; LINA
Štítky atomic emission spectrometry, inductively coupled plasma, Infrared Laser, laser ablation, LinA, steel
Změnil Změnil: prof. RNDr. Viktor Kanický, DrSc., učo 408. Změněno: 28. 6. 2007 16:41.
Anotace
Infrared laser ablation (IR-LA) was studied as a sample introduction technique for the analysis of steels by inductively coupled plasma atomic emission spectrometry (ICP-AES).A comparison of two IR-LA-ICP-AES systems based on Q-switched nanosecond Nd:YAG lasers was performed. The beam of the Lina-SPARK Atomizer (LSA Sarl, Cully, Switzerland) based on the Surelite I-20 laser (Continuum, USA) was moved along a circle. A Perkin-Elmer Optima 3000 DV ICP system was used for emission measurement both with lateral and axial viewing modes. A laboratory-made ablation system based on the Brilliant laser (Quantel) was coupled to a Jobin-Yvon 170 Ultrace ICP (lateral viewing, polychromator part employed). A sample was rotated along a circle during ablation. Linearity of calibration plots was verified at least up to 19 % Cr and 12 % Ni without internal standardization for both LA-ICP-AES systems. Other elements were examined up to 3 % Mo, 1.5 % Mn, 1.7 % Si and 0.15 % Cu. The reproducibility was in the range 5 - 1 %RSD for a mass percentage 0.5 - 20 % of steel constituents. The relative uncertainty on centroid of a calibration line was in the range from ą 4% to ą 12% for Cr, Ni, Mn, Mo, Si, and from ą 8 % to ą 19 % for Cu. The lowest determinable quantities were calculated based on calibrated ranges. Performances of both the IR-LA-ICP-AES were comparable.
Návaznosti
MSM 143100003, záměrNázev: Studium plazmochemických reakcí v neizotermickém nízkoteplotním plazmatu a jeho interakcí s povrchem pevných látek
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Studium plazmochemických reakcí v neizotermickém nízkoteplotním plazmatu a jeho interakcí s povrchem pevných látek
Zobrazeno: 20. 4. 2024 04:13