KANICKÝ, Viktor, Vítězslav OTRUBA, Karel NOVOTNÝ, Petr MUSIL and Jean-Michel MERMET. Calibration graphs for steels by IR laser ablation inductively coupled plasma atomic emission spectrometry (anglicky). Fresenius Journal of Analytical Chemistry. Berlin: Springer-Verlag, 2001, vol. 370, No 4, p. 387-392. ISSN 0937-0633.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Calibration graphs for steels by IR laser ablation inductively coupled plasma atomic emission spectrometry
Authors KANICKÝ, Viktor (203 Czech Republic, guarantor), Vítězslav OTRUBA (203 Czech Republic), Karel NOVOTNÝ (203 Czech Republic), Petr MUSIL (203 Czech Republic) and Jean-Michel MERMET.
Edition Fresenius Journal of Analytical Chemistry, Berlin, Springer-Verlag, 2001, 0937-0633.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10406 Analytical chemistry
Country of publisher Germany
Confidentiality degree is not subject to a state or trade secret
Impact factor Impact factor: 1.649
RIV identification code RIV/00216224:14310/01:00004314
Organization unit Faculty of Science
UT WoS 000170115100012
Keywords in English Laser ablation; Infrared laser; Inductively coupled plasma; Atomic emission spectrometry; Steel; LINA
Tags atomic emission spectrometry, inductively coupled plasma, Infrared Laser, laser ablation, LinA, steel
Changed by Changed by: prof. RNDr. Viktor Kanický, DrSc., učo 408. Changed: 28/6/2007 16:41.
Abstract
Infrared laser ablation (IR-LA) was studied as a sample introduction technique for the analysis of steels by inductively coupled plasma atomic emission spectrometry (ICP-AES).A comparison of two IR-LA-ICP-AES systems based on Q-switched nanosecond Nd:YAG lasers was performed. The beam of the Lina-SPARK Atomizer (LSA Sarl, Cully, Switzerland) based on the Surelite I-20 laser (Continuum, USA) was moved along a circle. A Perkin-Elmer Optima 3000 DV ICP system was used for emission measurement both with lateral and axial viewing modes. A laboratory-made ablation system based on the Brilliant laser (Quantel) was coupled to a Jobin-Yvon 170 Ultrace ICP (lateral viewing, polychromator part employed). A sample was rotated along a circle during ablation. Linearity of calibration plots was verified at least up to 19 % Cr and 12 % Ni without internal standardization for both LA-ICP-AES systems. Other elements were examined up to 3 % Mo, 1.5 % Mn, 1.7 % Si and 0.15 % Cu. The reproducibility was in the range 5 - 1 %RSD for a mass percentage 0.5 - 20 % of steel constituents. The relative uncertainty on centroid of a calibration line was in the range from ą 4% to ą 12% for Cr, Ni, Mn, Mo, Si, and from ą 8 % to ą 19 % for Cu. The lowest determinable quantities were calculated based on calibrated ranges. Performances of both the IR-LA-ICP-AES were comparable.