KOZUBEK, Michal, Petr MATULA, Heinz EIPEL a Michael HAUSMANN. Automated multi-view 3D image acquisition in human genome research. In 3D data processing, visualization and transmission. Los Alamitos: IEEE Computer Society. s. 91-98. ISBN 0-7695-1521-5. 2002.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Automated multi-view 3D image acquisition in human genome research
Autoři KOZUBEK, Michal (203 Česká republika, garant, domácí), Petr MATULA (203 Česká republika, domácí), Heinz EIPEL (276 Německo) a Michael HAUSMANN (276 Německo).
Vydání Los Alamitos, 3D data processing, visualization and transmission, s. 91-98, 2002.
Nakladatel IEEE Computer Society
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 20200 2.2 Electrical engineering, Electronic engineering, Information engineering
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Forma vydání tištěná verze "print"
Kód RIV RIV/00216224:14330/02:00006216
Organizační jednotka Fakulta informatiky
ISBN 0-7695-1521-5
UT WoS 000177028700016
Klíčová slova anglicky micro axial tomography; automated microscopy; high-resolution cytometry; FISH imaging; interphase cell nuclei
Štítky automated microscopy, FISH imaging, high-resolution cytometry, interphase cell nuclei, micro axial tomography
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: doc. RNDr. Petr Matula, Ph.D., učo 3019. Změněno: 12. 2. 2018 15:03.
Anotace
One of the main problems of 3D imaging in optical microscopy is unisotropic optical resolution of acquired 3D data. For instance in confocal laser scanning microscopy, axial resolution is 2-3 times worse than the lateral one. A sophisticated solution of this problem is so-called micro axial tomography that provides a good means for microscopic image acquisition of cells or sub-cellular components like cell nuclei with an improved resolution achieved by object tilting and acquisition of a series of mutually tilted 3D image data. Since the very early developments of micro axial tomography a considerable drawback of this method was a complicated image acquisition and processing procedure that requires much operator time. In order to solve this problem advanced microscopy and automated computer image acquisition and analysis were brought together. Special software that drives all hardware components required for automated micro axial tomography was developed. It performs multi-view 3D image acquisition as well as related image processing.
Návaznosti
MSM 143300002, záměrNázev: Využití počítačové analýzy obrazu v optické mikroskopii
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Využití počítačové analýzy obrazu v optické mikroskopii
VytisknoutZobrazeno: 19. 4. 2024 20:37