MACHÁT, Jiří, Viktor KANICKÝ a Vítězslav OTRUBA. Determination of Selenium in Blood Serum by Inductively Coupled Plasma Atomic Emission Spectrometry with Pneumatic Nebulization. Analytical and Bioanalytical Chemistry. Heidelberg: Springer, 2002, roč. 372, č. 4, s. 576-581. ISSN 1618-2642.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Determination of Selenium in Blood Serum by Inductively Coupled Plasma Atomic Emission Spectrometry with Pneumatic Nebulization
Autoři MACHÁT, Jiří (203 Česká republika), Viktor KANICKÝ (203 Česká republika) a Vítězslav OTRUBA (203 Česká republika, garant).
Vydání Analytical and Bioanalytical Chemistry, Heidelberg, Springer, 2002, 1618-2642.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
Kód RIV RIV/00216224:14310/02:00006344
Organizační jednotka Přírodovědecká fakulta
UT WoS 000176103100012
Klíčová slova anglicky Selenium speciation; Spectrometry; ICP-AES; Pneumatic nebulization
Štítky ICP-AES, Pneumatic nebulization, Selenium speciation, Spectrometry
Změnil Změnil: Mgr. Jiří Machát, Ph.D., učo 9852. Změněno: 20. 5. 2003 14:53.
Anotace
The possibility of determination of selenium in blood serum using inductively coupled plasma emission spectrometry with conventional pneumatic nebulization was studied. A high-resolution spectrometer (SBW = 6 pm) with laterally viewed ICP was employed. Analysis with conventional pneumatic nebulization could overcome laborious and demanding digestion, which is necessary for hydride generation. A pressure digestion with nitric acid at 160oC was sufficient to decrease the carbon content in serum sample to 5-10% of its original value. Spectral interference of the CN band was observed and mathematically corrected. It was found that the carbon-induced selenium line emission enhancement occurred even under ICP optimized conditions. A method of determination was developed and applied to the analysis of blood serum. True limit of detection in real samples is 0.01-0.02 mg/L and the limit of quantification (RSD 10%) is 0.03-0.07 mg/L using Se I 196.090 nm line at an integration time 10-2 s. The method was tested by analysis of porcine blood serum and serum reference material Seronorm MI 0181.