J 2004

Electrophoretically mediated microanalysis with partial filling technique and indirect or direct detection as a tool for inhibition studies of enzymatic reactions

TELNAROVÁ, Magdaléna, Soňa VYTISKOVÁ, Marta MONINCOVÁ and Zdeněk GLATZ

Basic information

Original name

Electrophoretically mediated microanalysis with partial filling technique and indirect or direct detection as a tool for inhibition studies of enzymatic reactions

Name in Czech

Studium inhibice enzymů kombinací metody EMMA s technikou částečného plnění kapiláry a přímou či nepřímou detekcí.

Authors

TELNAROVÁ, Magdaléna (203 Czech Republic), Soňa VYTISKOVÁ (203 Czech Republic), Marta MONINCOVÁ (203 Czech Republic) and Zdeněk GLATZ (203 Czech Republic, guarantor)

Edition

Electrophoresis, Weinheim, VHC, 2004, 0173-0835

Other information

Language

English

Type of outcome

Článek v odborném periodiku

Field of Study

10600 1.6 Biological sciences

Country of publisher

United States of America

Confidentiality degree

není předmětem státního či obchodního tajemství

Impact factor

Impact factor: 3.743

RIV identification code

RIV/00216224:14310/04:00009987

Organization unit

Faculty of Science

UT WoS

000221168700013

Keywords in English

inhibition; EMMA; partial filling technique; direct or indirect detection
Změněno: 19/5/2009 18:44, prof. RNDr. Zdeněk Glatz, CSc.

Abstract

V originále

The inhibition study of the model enzyme haloalkane dehalogenase from Sphingomonas paucimobilis was performed by a combination of the electrophoretically mediated microanalysis with a partial filling technique and indirect or direct detection. In this set-up, the part of capillary is filled with the buffer suitable for the enzymatic reaction 20 mM glycine buffer (pH 8.6) whereas, the rest of the capillary is filled with the background electrolyte optimal for separation of substrates and products. Two different background electrolytes and corresponding detection approaches were used to show the versatility of the developed method. The inhibition effect of 1,2-dichloroethane on the dehalogenation of brominated substrate 1-bromobutane was studied by means of 10 mM chromate - 0.1 mM cetyltrimethylammonium bromide (pH 9.2) in combination with an indirect detection or 0.1 M beta-alanine - hydrochloric acid (pH 3.5) in combination with a direct detection. The method was used not only to estimate inhibition constant Ki 0.44 mM by means of indirect detection method and 0.63 mM by means of direct detection method but also to determine the inhibition type. Compared to spectrophotometric and other discontinuous assays, the method is rapid, can be automated, and requires only small amount of reagents that is especially important in the case of enzymes and inhibitors. Consequently it has a great potential for such determinations in other enzyme-inhibitor systems.

In Czech

Jedna se o studium inhibice enzymů kombinací metody EMMA s technikou částečného plnění kapiláry a přímou či nepřímou detekcí.

Links

GA203/03/1125, research and development project
Name: Využití kapilární zónové elektroforézy pro studium enzymů
Investor: Czech Science Foundation, Application of capillary zone electrophoresis for the study of enzymes
MSM 143100005, plan (intention)
Name: Strukturně-funkční vztahy biomolekul a jejich role v metabolismu
Investor: Ministry of Education, Youth and Sports of the CR, Biomolecular Structure-function Relationships and their role in the Metabolism