Detailed Information on Publication Record
2004
Determination of inorganic arsenic species As(III) and As(V) by high performance liquid chromatography with hydride generation atomic absorption spectrometry detection
NIEDZIELSKI, Przemyslaw, Marcin SIEPAK and Karel NOVOTNÝBasic information
Original name
Determination of inorganic arsenic species As(III) and As(V) by high performance liquid chromatography with hydride generation atomic absorption spectrometry detection
Name in Czech
Stanovení anorganických specií arsenu As(III) a As(V) vysokoúčinnou kapalinovou chromatografií s detekcí atomovou absorpční spektrometrií s generací hydridu
Authors
NIEDZIELSKI, Przemyslaw (616 Poland, guarantor), Marcin SIEPAK (616 Poland) and Karel NOVOTNÝ (203 Czech Republic)
Edition
Central European Journal of Chemistry, Warsaw, 2004, 1644-3624
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10406 Analytical chemistry
Country of publisher
Poland
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 0.171
RIV identification code
RIV/00216224:14310/04:00010231
Organization unit
Faculty of Science
UT WoS
000222237700005
Keywords in English
speciation; hyphenated techniques; arsenic; hydride generation absorption atomic spectrometry; high performance liquid chromatography
Změněno: 11/8/2009 14:38, doc. Mgr. Karel Novotný, Ph.D.
V originále
The paper presents the principles and advantages of a technique combining high performance liquid chromatography and hydride generation atomic absorption spectrometry (HPLC-HGAAS) applied to speciation analysis of inorganic species of arsenic As(III) and As(V) in ground water samples. With separation of the arsenic species on an ion-exchange column in the chromatographic system and their detection by the hydride generation atomic absorption spectrometry, the separation of the analytical signals of the arsenic species was excellent at the limits of determination of 1.5 ng/ml As(III) and 2.2 ng/ml As(V) and RSD of 4.3% and 7.8% for the concentration of 25 ng/ml. The hyphenated technique has been applied for determination of arsenic in polluted ground water in the course of the study on migration of micropollutants. For total arsenic concentration two independent methods: HGICP-OES and HGAAS were used for comparison of results of real samples analysis.
In Czech
Článek se věnuje principům a výhodám techniky spojující vysokoúčinnou kapalinovou chromatografii s detekcí atomovou absorpční spektrometrií s generací hydridu (HPLC-HGAAS) aplikované na speciaci anorganických forem arsenu As(III) a As(V) v podzemních vodách. Při separaci specií arsenu na iontově-výměnné chromatografické koloně s detekcí HG-AAS bylo dosaženo výborných mezí stanovení 1.5 ng/ml pro As(III) a 2.2 ng/ml pro As(V) a relativní směrodatné odchylky 4.3% a 7.8% pro koncentraci 25/ng/ml. Technika byla použita pro studium migrace arsenu jako mikropolutantu v znečištěných podzemních vodách. Pro stanovení celkového obsahu arsenu byly pro srovnání použity dvě nezávislé metody: HGICP-OES a HGAAS.
Links
VS97020, research and development project |
|