a 2004

Intima-media thickness of carotid arteries and heart rate and blood pressure variability in normotensive and hypertensive subjects

NOVÁKOVÁ, Zuzana, Bořivoj SEMRÁD, Bohumil FIŠER, Růžena LÁBROVÁ, Eva DUFKOVÁ et. al.

Basic information

Original name

Intima-media thickness of carotid arteries and heart rate and blood pressure variability in normotensive and hypertensive subjects

Name in Czech

Tloušťka intimy-medie karotických tepen a variabilita tepové frekvence a krevního tlaku u normotenzních a hypertenzních osob

Authors

NOVÁKOVÁ, Zuzana (203 Czech Republic, guarantor), Bořivoj SEMRÁD (203 Czech Republic), Bohumil FIŠER (203 Czech Republic), Růžena LÁBROVÁ (203 Czech Republic), Eva DUFKOVÁ (203 Czech Republic), Petra VYSOČANOVÁ (203 Czech Republic), Nataša HONZÍKOVÁ (203 Czech Republic) and Eva ZÁVODNÁ (203 Czech Republic)

Edition

Noninvasive methods in cardiology 2.11.2004, Book of abstracts, Congress MEFA 2004, 2004

Other information

Language

English

Type of outcome

Konferenční abstrakt

Field of Study

30105 Physiology

Country of publisher

Czech Republic

Confidentiality degree

není předmětem státního či obchodního tajemství

RIV identification code

RIV/00216224:14110/04:00010832

Organization unit

Faculty of Medicine

ISBN

80-86607-14-3

Keywords in English

intima-media thickness; carotid wall; heart rate variability; blood pressure variability; Holter monitoring
Změněno: 1/4/2010 17:58, MUDr. Bc. Eva Závodná, Ph.D.

Abstract

V originále

Decreased heart rate variability is a marker of increased risk of sudden cardiac death. For this reason the relationship between intima-media thickness of carotid artery (IMT) and short time and 24-hours heart rate variability together with blood pressure variability was followed in the present study. The relation between intima-media thickness and heart-rate variability determined from 24-hours Holter monitoring was not found. Decreased short time heart-rate variabilities of 5-minute recording by Finapres correspond to decreased baroreflex in patients with increased intima-media thickness.

In Czech

Variabilita tepové frekvence (HRV) se používá ke zjišťování rizika náhlé srdeční smrti. Nás zajímal vztah tloušťky intimy-medie karotických tepen a variability jak tepové frekvence , tak krevního tlaku. Variabilita tepové frekvence určovaná z 24-hod EKG záznamu nekorelovala s tloušťkou stěny karotid. Ale krátkodobá HRV(sledována z 5minutového záznamu krevního tlaku z prstových arterií)u osob z hypertenzí byla snížená a korelovala se snížením citlivosti baroreflexu a zvětšenou tloušťkou karotických tepen u těchto osob.

Links

NA7362, research and development project
Name: VZTAH CITLIVOSTI BAROREFLEXU K PARAMETRŮM STĚNY A. CAROTIS ZJIŠŤOVANÝM SONOGRAFICKY
Investor: Ministry of Health of the CR