SOLNÁ, Renáta, Eva DOCK, Alexander CHRISTENSON, Margrethe WINTER-NIELSEN, Christine CARLSSON, Jenny EMNÉUS, Tautgirdas RUZGAS a Petr SKLÁDAL. Amperometric screen-printed biosensor arrays with co-immobilised oxidoreductases and cholinesterases. Analytica Chimica Acta. Amsterdam: Elsevier Science Publishers, 2005, roč. 528, č. 1, s. 9-19. ISSN 0003-2670.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Amperometric screen-printed biosensor arrays with co-immobilised oxidoreductases and cholinesterases
Název česky Amperometrické sítotisková biosensorová pole s koimobilisovanými oxidoreduktasami a cholinesterasami
Autoři SOLNÁ, Renáta (203 Česká republika), Eva DOCK (752 Švédsko), Alexander CHRISTENSON (752 Švédsko), Margrethe WINTER-NIELSEN (208 Dánsko), Christine CARLSSON (752 Švédsko), Jenny EMNÉUS (752 Švédsko), Tautgirdas RUZGAS (752 Švédsko) a Petr SKLÁDAL (203 Česká republika, garant).
Vydání Analytica Chimica Acta, Amsterdam, Elsevier Science Publishers, 2005, 0003-2670.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10600 1.6 Biological sciences
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 2.760
Kód RIV RIV/00216224:14310/05:00013673
Organizační jednotka Přírodovědecká fakulta
UT WoS 000226455600002
Klíčová slova anglicky amperometric multienzyme sensor; steady state system; cholinesterase; oxidoreductase; phenoks; pesticides; wastewater; multivariate-analysis
Štítky amperometric multienzyme sensor, Cholinesterase, multivariate-analysis, oxidoreductase, pesticides, phenoks, steady state system, wastewater
Změnil Změnil: prof. RNDr. Petr Skládal, CSc., učo 2202. Změněno: 7. 6. 2005 16:04.
Anotace
Amperometric screen-printed biosensor arrays for detection of pesticides (organophosphates and carbamates) and phenols have been developed. Cholinesterases (AChE and BChE), tyrosinase (TYR), peroxidases (SBP. soybean and HRP. horseradish) and cellobiose dehydrogenase (CDH) were combined on the same array consisting of one Ag/AgCl reference electrode surrounded by eight radially distributed working electrodes of either carbon or platinum. Mainly cross-linking with glutaraldehyde was employed for enzyme immobilisation. The substrates for the enzymes were acetylthiocholine for cholinesterases (ChEs), cellobiose for CDH and hydrogen peroxide for peroxidases. Hydrogen peroxide was generated in the presence of glucose by co-immobilised glucose oxidase (GOx). All measurements were performed in an electrochemical steady state system specially constructed for eight channel screen-printed electrode arrays. The achieved relative standard deviation values calculated for different enzyme substrates (10 measurements) were typically below 7% and one assay was completed within less than 10 min. The detection limits for pesticides and phenols were in the nanomolar and micromolar ranges, respectively. The developed biosensor array was evaluated on wastewater samples. To simplify interpretation of results. the measured data were created with multivariate analysis-principal component analysis (PCA).
Anotace česky
Amperometrické sítotiskové multielektrodové biosensory byly připraveny použitím cholinesteras (AChE a BChE), tyrosinasy, celobiosa dehydrogenasy a peroxidas (křenová a sojová) na jediném sensoru. Byly optimalisovány podmínky měření. Testované vzorky odpadních vod pak byly klasifikovány pomocí chemometrické multivariační analysy.
Návaznosti
MSM0021622413, záměrNázev: Proteiny v metabolismu a při interakci organismů s prostředím
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Proteiny v metabolismu a při interakci organismů s prostředím
VytisknoutZobrazeno: 11. 5. 2024 00:16