Detailed Information on Publication Record
2005
Elimination voltammetry with linear scan as a new detection method for DNA sensors
TRNKOVÁ, Libuše, František JELEN, Jitka PETRLOVÁ, Vojtěch ADAM, David POTĚŠIL et. al.Basic information
Original name
Elimination voltammetry with linear scan as a new detection method for DNA sensors
Name in Czech
Eliminační voltametrie s lineárním skenem jako nová detekční metoda pro DNA senzory
Authors
TRNKOVÁ, Libuše (203 Czech Republic, guarantor), František JELEN (203 Czech Republic), Jitka PETRLOVÁ (203 Czech Republic), Vojtěch ADAM (203 Czech Republic), David POTĚŠIL (203 Czech Republic) and René KIZEK (203 Czech Republic)
Edition
SENSORS, 2005, 1424-8220
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10405 Electrochemistry
Country of publisher
Czech Republic
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 1.208
RIV identification code
RIV/00216224:14310/05:00014629
Organization unit
Faculty of Science
UT WoS
000233333900009
Keywords in English
oligodeoxynucleotide; DNA biosensor; linear sweep voltammetry; elimination voltammetry with linear scan; reduction of adenine and cytosine; mercury electrode; sequence of nucleotides
Tags
Změněno: 31/1/2006 14:36, prof. RNDr. Libuše Trnková, CSc.
V originále
The paper describes successful coupling of adsorptive transfer stripping (AdTS) and elimination voltammetry with linear scan (EVLS) for the resolution of reduction signals of cytosine ( C) and adenine ( A) residues in hetero-oligodeoxynucleotides (ODNs). Short ODNs (9-mers and 20-mers) were adsorbed from a small volume on a hanging mercury drop electrode (HMDE). After washing of the ODN-modified electrode by water and its transferring to an electrochemical cell, voltammetric curves were measured. The AdTS EVLS was able to determine of C/A ratio of ODNs through the elimination function conserving the diffusion current component and eliminating kinetic and charging current components. This function, which provides the elimination signal in a peak-counterpeak form, increased the current sensitivity for A and C resolution, and for the recognition of bases sequences in ODN chains. Optimal conditions of elimination experiments such as pH, time of adsorption, and scan rate were found. The combination of EVLS with AdTS procedure can be considered as a new detection method in a DNA sensor.
In Czech
Tato práce popistuje
Links
MSM0021622412, plan (intention) |
|