PŘIBYL, Jan and Petr SKLÁDAL. Development of a combined setup for simultaneous detection of total and glycated haemoglobin content in blood samples. Biosensors & Bioelectronics. Oxford: Elsevier Advanced Technology, 2006, vol. 21, No 10, p. 1952-1959. ISSN 0956-5663.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Development of a combined setup for simultaneous detection of total and glycated haemoglobin content in blood samples
Name in Czech Vývoj kombinovaného systému pro současné stanovení celkového a glykovaného hemoglobinu ve vzorcích krve
Authors PŘIBYL, Jan (203 Czech Republic) and Petr SKLÁDAL (203 Czech Republic, guarantor).
Edition Biosensors & Bioelectronics, Oxford, Elsevier Advanced Technology, 2006, 0956-5663.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10600 1.6 Biological sciences
Country of publisher United Kingdom of Great Britain and Northern Ireland
Confidentiality degree is not subject to a state or trade secret
Impact factor Impact factor: 4.132
RIV identification code RIV/00216224:14310/06:00016801
Organization unit Faculty of Science
UT WoS 000236756100015
Keywords in English Biosensor; Piezoelectric sensor; Quartz crystal microbalance; Flow injection analysis
Tags biosensor, Flow injection analysis, Piezoelectric sensor, Quartz crystal microbalance
Tags International impact, Reviewed
Changed by Changed by: prof. RNDr. Petr Skládal, CSc., učo 2202. Changed: 16/6/2007 22:32.
Abstract
An original setup for analysis of glycated haemoglobin (HbA,) in blood is reported. The construction employed a combination of the piezoelectric biosensor for glycated haemoglobin and the flow-through photometric sensor for total haemoglobin (Hb). The modification of gold electrodes with 3-aminophenylboronic acid (APBA) as a specific ligand was studied; the chemisorbed conjugate of APBA with a long-chain thiocompound provided the best affinity for Hb(A1c). The effect of various operating parameters, such as flow rate and instrumental setup, was optimised. The total haemoglobin content was analysed as absorbance of the haemoglobin-cyanide derivative at 540 nm. Only one standard (calibrator) diluted in various ratio was necessary for calibration and 1 mu l of blood was sufficient for analysis. The full range of Hb(A1c) content (4-15%) in blood can be analysed; the working ranges of total and glycated haemoglobin were 50-2000 and 10-90 mu g/ml, respectively. The developed method was successfully evaluated on blood samples collected from diabetics.
Abstract (in Czech)
Byl vyvinut kombinovaný systém na bázi piezoelektrického biosensoru s imobilizovanou kyselinou aminofenylboritou pro specifickou detekci glykvaného hemoglobinu, paralelně se spektrofotometricky stanovuje celkový hemoglobin. Systém je spojen s automatický průtočným analyzátorem FIAlab a je vhodný pro měření vzorků krve.