NOVÁKOVÁ, Zuzana, Nataša HONZÍKOVÁ, Antonín KRTIČKA, Bohumil FIŠER, Eva ZÁVODNÁ and Jiří MOUDR. Frequency of the blood-pressure spectral peak around 0.1 Hz and baroreflex sensitivity in normotensives and hypertensives. In Analysis of Biomedical signals and images 18-th Biennial International Eurasip Conference Biosignal 2006. 1st ed. Brno: Vutium press, 2006, p. 339-341. ISBN 80-214-3152-0.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Frequency of the blood-pressure spectral peak around 0.1 Hz and baroreflex sensitivity in normotensives and hypertensives
Name in Czech Frekvence maxima ve spektru krevního tlaku a citlivost baroreflexu u normotoniků a hypertoniků
Authors NOVÁKOVÁ, Zuzana (203 Czech Republic, guarantor), Nataša HONZÍKOVÁ (203 Czech Republic), Antonín KRTIČKA (203 Czech Republic), Bohumil FIŠER (203 Czech Republic), Eva ZÁVODNÁ (203 Czech Republic) and Jiří MOUDR (203 Czech Republic).
Edition 1. vyd. Brno, Analysis of Biomedical signals and images 18-th Biennial International Eurasip Conference Biosignal 2006, p. 339-341, 3 pp. 2006.
Publisher Vutium press
Other information
Original language English
Type of outcome Proceedings paper
Field of Study 30105 Physiology
Country of publisher Czech Republic
Confidentiality degree is not subject to a state or trade secret
RIV identification code RIV/00216224:14110/06:00018013
Organization unit Faculty of Medicine
ISBN 80-214-3152-0
Keywords (in Czech) Baroreflex, tlak krve, spektrální analýza
Keywords in English baroreflex sensitivity; blood pressure; spectral analysis
Tags baroreflex sensitivity, Blood pressure, spectral analysis
Changed by Changed by: prof. MUDr. Bohumil Fišer, CSc., učo 2725. Changed: 19/6/2009 12:54.
Abstract
Baroreflex sensitivty correlated positively with the frquency of the resonance peak in the range of 0.05-0.15 Hz in blood-pressure spectra in both, healthy subjects and yhpertensives. This result was independent of determination of baroreflex sensitivity by cross-spectral method or by alpha index
Abstract (in Czech)
Citlivost baroreflexu koreloval pozitivně s frekvencí rezonančního maxima v oblasti 0.05-0.15 Hz ve spektru krevního tlaku u normotoniků i hypertoniků dohromady. Tento výsledek byl nezávislý na stanovení citlivosti baroreflexu vzájemnou-spektrální metodou nebo alfa indexem.
Links
MSM0021622402, plan (intention)Name: Časná diagnostika a léčba kardiovaskulárních chorob
Investor: Ministry of Education, Youth and Sports of the CR, Early diagnostics and treatment of cardiovascular diseases
PrintDisplayed: 12/5/2024 20:14