Detailed Information on Publication Record
2006
UV and IR laser ablation study of natural organic powdered materials—an example: ICP-OES with laser ablation of spiked infant formula cast pellets
HOLÁ, Markéta, Pavel KRÁSENSKÝ, Vítězslav OTRUBA and Viktor KANICKÝBasic information
Original name
UV and IR laser ablation study of natural organic powdered materials—an example: ICP-OES with laser ablation of spiked infant formula cast pellets
Name in Czech
UV a IR laserová ablace organických práškových materiálů - příklad: ICP-OES s laserovou ablací spikovaných odlévaných tablet kojeneckého sušeného mléka
Authors
HOLÁ, Markéta (203 Czech Republic, guarantor), Pavel KRÁSENSKÝ (203 Czech Republic), Vítězslav OTRUBA (203 Czech Republic) and Viktor KANICKÝ (203 Czech Republic)
Edition
Journal of analytical atomic spectrometry, Cambridge, Royal Society of Chemistry, 2006, 0267-9477
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10406 Analytical chemistry
Country of publisher
United Kingdom of Great Britain and Northern Ireland
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 3.630
RIV identification code
RIV/00216224:14310/06:00018199
Organization unit
Faculty of Science
UT WoS
000240082600018
Keywords in English
laser ablation; powder; infant formula; inductively coupled plasma; atomic emission spectrometry
Tags
Tags
International impact, Reviewed
Změněno: 2/7/2009 09:32, Mgr. Markéta Holá, Ph.D.
V originále
Laser ablation (LA) sample introduction into inductively coupled plasma optical emission spectrometry (ICP-OES) was used for powdered infant food formula being representative of samples with an organic matrix. Milk samples enriched with eight naturally occurring elements were presented for LA-ICP-OES experiments as cast epoxy resin disks. For Ca, Cu, Fe, Mg and Zn, a performance of IR (1064 nm) and UV (266 nm) ablation was compared in a fixed spot mode (UV) and in a scanning mode (both UV and IR). Signal vs. content dependences proved to be linear both with and w/o the internal standard Ca (IS). Using the IS the linear regression parameters for the scanning mode were improved for both UV and IR ablation. The UV fixed spot ablation provided the closest correlation and so, except for Cu (low content), repeatability for all elements of interest did not exceed 10% RSD. Lowest determinable quantities were 0.06% Ca, 0.008% Mg, 0.0005% Cu, 0.001% Fe and 0.0008% Zn. Condensation of Zn on ejected particles was observed at the UV ablation.
In Czech
Laserová ablace (LA) byla jako metoda přímého zavádění pevných vzorků do indukčně vázaného plazmatu ve spojení s optickou emisní spektrometrií (LA-ICP-OES) použita pro práškové kojenecké mléko jako materiálu s organickou matricí. Vzorky mléka obohacené o osm běžně se vyskytujících prvků byly připraveny pro ablaci ve formě odlévaných tablet s epoxidovou pryskyřicí. Pro Ca, Cu, Fe, Mg a Zn byla srovnána IR (1064 nm) a UV (266 nm) ablace ve fixním módu (UV) a ve skenovacím módu (UV i IR). Odezva Signálu vs. obsahu prvků se ukázala jako lineární jak bez tak s použitím Ca jako porovnávacího prvku (IS). S použitím IS se lineární regrese pro skenovací mód vylepšila pro UV i IR ablaci. Fixní UV ablace poskytovala nejlepší korelaci vyjma Cu (nízké obsahy), opakovatelnost pro všechny prvky nepřekročila 10% RSD, Nejnižší stanovitelná množství byla 0.06% Ca, 0.008% Mg, 0.0005% Cu, 0.001% Fe and 0.0008% Zn. Při UV ablaci bylo pozorováno usazování Zn na uvolněných částicích.
Links
MSM0021622411, plan (intention) |
| ||
MSM0021622412, plan (intention) |
|