NĚMEC, Tomáš and Zdeněk GLATZ. Integration of short-end injection procedure into EMMA methodology. Journal of Chromatography A. Amsterdam: Elsevier, 2007, vol. 1155, 1-2, p. 206-213, 5 pp. ISSN 0021-9673.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Integration of short-end injection procedure into EMMA methodology.
Name in Czech Spojeni techniky dávkování z krátkého konce kapiláry s metodou EMMA
Authors NĚMEC, Tomáš (203 Czech Republic) and Zdeněk GLATZ (203 Czech Republic, guarantor).
Edition Journal of Chromatography A, Amsterdam, Elsevier, 2007, 0021-9673.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10600 1.6 Biological sciences
Country of publisher Netherlands
Confidentiality degree is not subject to a state or trade secret
Impact factor Impact factor: 3.641
RIV identification code RIV/00216224:14310/07:00020172
Organization unit Faculty of Science
UT WoS 000247855200012
Keywords in English CE; EMMA substrate; inhibition; haloalkane dehalogenase
Tags CE, EMMA substrate, haloalkane dehalogenase, inhibition
Tags International impact, Reviewed
Changed by Changed by: Mgr. Petr Bureš, učo 40751. Changed: 16/7/2008 14:59.
Abstract
The possibility of integration of the short end injection mode in the EMMA methodology is demonstrated in this work on the kinetic studies of haloalkane dehalogenase and rhodanese enzymatic reactions. The essential validations of the EMMA methods combined with the short end and long end injection modes were performed first to confirm their accuracy. The qualitative and quantitative parameters of both approaches such as repetabilities of migration times and peak areas, limits of detection and correlation coefficients were in acceptable ranges. In addition estimated Michaelis constants for the corresponding substrate(s) were comparable being in accordance with previous literature data. Moreover the ping-pong reaction mechanism of rhodanese reaction was confirmed by means of both injection modes. This combination thus preserves the benefits of these instrumental approaches. Whereas the short-end injection procedure brought 5 6.5 times reduction of the analysis time and 2.5 4 times increase of the sensitivity, the EMMA methodology allowed full automatization of the assays while the whole kinetic studies needed only 20 ul of corresponding enzyme preparation.
Abstract (in Czech)
Byla integravána technika dávkování z krátkého konce kapiláry do metody EMMA, která přinesla nejenom zkrácení doby analýzy, ale rovněž zvýšení citlivosti detekce.
Links
GA203/06/0047, research and development projectName: Využití kapilární elektroforézy pro studium metabolismu léčiv
Investor: Czech Science Foundation, Capillary electrophoresis as a tool for the drug-metabolism studies
LC06023, research and development projectName: Integrované bioanalytické technologie pro mikroanalýzy a diagnostiku s využitím LIF a hmotnostní spektrometrie
Investor: Ministry of Education, Youth and Sports of the CR
MSM0021622413, plan (intention)Name: Proteiny v metabolismu a při interakci organismů s prostředím
Investor: Ministry of Education, Youth and Sports of the CR, Proteins in metabolism and interaction of organisms with the environment
PrintDisplayed: 2/9/2024 13:28