Detailed Information on Publication Record
2007
Palladium biosensor
ADAM, Vojtěch, Pavel HANUŠTIAK, René KIZEK, Soňa KŘÍŽKOVÁ, Libuše TRNKOVÁ et. al.Basic information
Original name
Palladium biosensor
Name in Czech
Paladiový biosenzor
Authors
ADAM, Vojtěch (203 Czech Republic), Pavel HANUŠTIAK (203 Czech Republic), René KIZEK (203 Czech Republic, guarantor), Soňa KŘÍŽKOVÁ (203 Czech Republic), Libuše TRNKOVÁ (203 Czech Republic, belonging to the institution), Miroslava BEKLOVÁ (203 Czech Republic), Josef ZEHNÁLEK (203 Czech Republic), Aleš HORNA (203 Czech Republic, belonging to the institution) and Bernd SURES (191 Croatia)
Edition
Electroanalysis, Spolková republika Německo, 2007, 1040-0397
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10405 Electrochemistry
Country of publisher
Germany
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 2.949
RIV identification code
RIV/00216224:14310/07:00050872
Organization unit
Faculty of Science
UT WoS
000249630900007
Keywords in English
Palladium; biosensor; electrochemistry
Tags
Změněno: 12/3/2012 10:07, prof. RNDr. Libuše Trnková, CSc.
V originále
In this paper we proposed a palladium(II) biosensor. The biosensor is based on determining of interactions between palladium(II) and metallothionein modified hanging mercury drop electrode by means of differential pulse voltammetry. We studied influence of two supporting electrolytes (potassium or sodium chloride) on the signals of the biosensor. Based on the results obtained we found potassium chloride (0.05 M) as the most suitable supporting electrolyte to determine palladium(II). The detection limit of the biosensor for palladium ions was evaluated as 100 nM with RSD about 10%. Moreover, we utilized the biosensor for measurement of the target molecule in the presence of human blood serum and human urine.
In Czech
V této práci jsme navrhli paladiový (II) biosenzor. Biosensor je založen na určování interakce mezi paladiem (II) a metalothioneinem modifikovanou elektrodou se rtuťovou kapkou pomocí diferenční pulzní voltametrie. Studovali jsme vliv dvou podpůrných elektrolytů (KCl nebo NaCl) na signál biosensoru. Na základě obdržených výsledků jsme shledali KCl (0,05 M) jako nejvhodnější podpůrný elektrolyt pro určení paladia (II). Detekční limit pro biosenzor paladiových iontů byl zhodnocen 100 nM s RSD asi 10%. Navíc, jsme použili biosenzor pro měření vybraných molekul přítomných v lidském krevním séru a moči.
Links
MSM0021622412, plan (intention) |
|