Detailed Information on Publication Record
2007
Electroanalysis of plant thiols
ŠUPÁLKOVÁ, Veronika, Dalibor HÚSKA, Václav DIOPAN, Pavel HANUŠTIAK, Ondřej ZÍTKA et. al.Basic information
Original name
Electroanalysis of plant thiols
Name in Czech
Elektroanalýza rostlinných thiolů
Authors
ŠUPÁLKOVÁ, Veronika (203 Czech Republic), Dalibor HÚSKA (203 Czech Republic), Václav DIOPAN (203 Czech Republic), Pavel HANUŠTIAK (203 Czech Republic), Ondřej ZÍTKA (203 Czech Republic), Karel STEJSKAL (203 Czech Republic), Jiří BALOUN (203 Czech Republic), Jiří PIKULA (203 Czech Republic), Ladislav HAVEL (203 Czech Republic), Josef ZEHNÁLEK (203 Czech Republic), Vojtěch ADAM (203 Czech Republic), Libuše TRNKOVÁ (203 Czech Republic, belonging to the institution), Miroslava BEKLOVÁ (203 Czech Republic) and René KIZEK (203 Czech Republic, guarantor)
Edition
Sensors, 2007, 1424-8220
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10405 Electrochemistry
Country of publisher
Switzerland
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 1.573
RIV identification code
RIV/00216224:14310/07:00050873
Organization unit
Faculty of Science
UT WoS
000247556600006
Keywords in English
thiols; cadmium; electrochemical detection
Tags
Změněno: 10/4/2012 10:18, Ing. Zdeňka Rašková
V originále
Due to unique physico-chemical properties of --SH moiety thiols comprise wide group of biologically important compounds. A review devoted to biological functions of glutathione and phytochelatins with literature survey of methods used to analysis of these compounds and their interactions with cadmium(II) ions and Murashige-Skoog medium is presented. For these purposes electrochemical techniques are used. Moreover, we revealed the effect of three different cadmium concentrations (0, 10 and 100 uM) on cadmium uptake and thiols content in maize plants during 192 hours long experiments using differential pulse anodic stripping voltammetry to detect cadmium(II) ions and high performance liquid chromatography with electrochemical detection to determine glutathione. Cadmium concentration determined in tissues of the plants cultivated in nutrient solution containing 10 uM Cd was very low up to 96 hours long exposition and then the concentration of Cd markedly increased. On the contrary, the addition of 100 uM Cd caused an immediate sharp increase in all maize plant parts to 96 hours Cd exposition but subsequently the Cd concentration increased more slowly. A high performance liquid chromatography with electrochemical detection was used for glutathione determination in treated maize plants after 96 and 192 hours of treatment. The highest total content of glutathione per one plant was 6 ug (96 h, 10 uM Cd) in comparison with non-treated plant (control) where glutathione content was 1.5 ug.
In Czech
Protože SH- skupina má unikátní fyzikálně-chemické vlastnosti, obsahují ji četné biologický důležité látky. Literární přehled popisuje biologickou funkci glutathionu a fytochelatinů a elektrochemických metod užitých k analýze těchto látek a jejich interakci s kademnatými ionty. Popsali jsme efekt 3 různých koncentrací kadmia (0, 10 a 100 uM), na jeho příjmu a na obsahu glutathionu v rostlinách kukuřice během expozice trvající 192 hodin. Kadmium jsme měřili pomocí diferenční pulsní anodickou rozpouštěcí volatmetrií. Glutathion byl stanovován pomocí HPLC s elektrochemickou detekcí. Koncentrace kadmia ve tkáních rostlin kultivovaných v roztoku s nutriety a 10 uM roztokem kadmia byl velmi nízký do 96 hodin po začátku expozice a pak se koncentrace značně se zvýšila. Naopak 100 uM koncentrace Cd způsobila bezprostřední zvýšení jeho obsahu ve všech částí rostlin kukuřice do 96 hodin, ale poté se koncentrace zvyšovala jen pozvolna. Glutathion byl stanoven 96 a 192 hodin po expozici. Nejvyšší totální obsah glutathionu na jednu rostlinu byl 6 ug (96, 10uM Cd) v porovnání s neexponovanými rostlinami (1.5 ug).
Links
MSM0021622412, plan (intention) |
|