Application of coulometric detection to the molecular biochemistry
ADAM, Vojtěch, Václav DIOPAN, Miroslava BEKLOVÁ, Aleš HORNA, Ladislav ZEMAN et. al.Basic information
Original name
Application of coulometric detection to the molecular biochemistry
Name in Czech
Aplikace coulometrické detekce v molekulární biochemii
Authors
ADAM, Vojtěch (203 Czech Republic, belonging to the institution), Václav DIOPAN (203 Czech Republic), Miroslava BEKLOVÁ (203 Czech Republic), Aleš HORNA (203 Czech Republic), Ladislav ZEMAN (203 Czech Republic), Libuše TRNKOVÁ (203 Czech Republic, guarantor, belonging to the institution) and René KIZEK (203 Czech Republic, belonging to the institution)
Edition
Univerzita Pardubice, Vitamins 2007- Nutrition and Diagnostics, p. 96-97, 2 pp. 2007
Publisher
Univerzita Pardubice
Other information
Language
English
Type of outcome
Stať ve sborníku
Field of Study
10600 1.6 Biological sciences
Country of publisher
Czech Republic
Confidentiality degree
není předmětem státního či obchodního tajemství
RIV identification code
RIV/00216224:14310/07:00050875
Organization unit
Faculty of Science
ISBN
978-80-7194-937-4
Keywords in English
Coulometric detection; nucleic acids; liquid chromatography
Změněno: 22/2/2012 13:11, Ing. Zdeňka Rašková
V originále
In the present work, we aimed on optimizing liquid chromatography coupled with twelve channel coulometric detector to detect markers of oxidative damaging of nucleic acids. Primarily, we aimed on investigating of influence of fundamental experimental conditions such as composition of mobile phase and its flow rate, column temperature and working electrodes potential on current responses of 8-hydroxyguanosine. The optimized conditions were as follows -- mobile phase: acetate buffer with flow rate of 0.5 ml.min-1, working electrodes potential: -400 mV, column temperature: 30 degree of C. The detection limit (3 S/N) was evaluated as tens of femtomoles per injection. Based on the results obtained the technique could be used for analysis of clinical samples.
In Czech
V této práci jsme se snažili optimalizovat kapalinovou chromatografii s dvanáctikanálovým coulometrickým detektorem pro detekci markrů oxidačního poškození nukleových kyselin. Nejprve bylo snahou zjistit vliv základních experimentálních podmínek jako je složení mobilní fáze a rychlos průtoku, teplota kolony a potenciál pracovních elektrod, na reakci 8-hydroxyguanosinu. Optimální podmínky byli následující - mobilní fáze: acetátový pufr s rychlostí průtoku 0.5 ml.min-1, potenciál pracovních elektrod: -40mV, teplota kolony 30 ct. C. Detekční limit (3 S/N)zhodnocen deset femtomolů na injekci. Na základě obdržených výsledků je technika vhodná pro analýzu klinických vzorků.