Detailed Information on Publication Record
2007
Comparison of energy dispersive X-ray fluorescence spectrometry, inductively coupled plasma optical emission spectrometry and laser ablation with plasma spectrometry in the elemental analysis of experimentally contaminated archive agricultural soils
JANOTKOVÁ, Ivona, Markéta HOLÁ, Jiří PINKAS, Vlastimil KUBÁŇ, Ilse STEFFAN et. al.Basic information
Original name
Comparison of energy dispersive X-ray fluorescence spectrometry, inductively coupled plasma optical emission spectrometry and laser ablation with plasma spectrometry in the elemental analysis of experimentally contaminated archive agricultural soils
Name in Czech
Srovnání energiově disperzní RTG fluorescenční spektrometrie, optické emisní spektrometrie s indukčně vázaným plazmatem a laserové ablace s plazmovou spektrometríí při prvkové analýze experimentálně kontaminovaných archivních vzorků půd
Authors
JANOTKOVÁ, Ivona, Markéta HOLÁ, Jiří PINKAS, Vlastimil KUBÁŇ, Ilse STEFFAN, Jiří ZBÍRAL and Viktor KANICKÝ
Edition
Abstract book of colloquium spectroscopicum internationale XXXV, 2007
Other information
Language
English
Type of outcome
Konferenční abstrakt
Field of Study
10402 Inorganic and nuclear chemistry
Country of publisher
China
Confidentiality degree
není předmětem státního či obchodního tajemství
Organization unit
Faculty of Science
ISBN
978-7-5615-2870-9
Keywords in English
energy dispersive X-ray spectrometry; laser ablation; inductively coupled plasma; plasma spectrometry; optical emission spectrometry; mass spectrometry; agricultural soil; sequential extraction; bioavailability; pellet
Tags
Tags
International impact
Změněno: 29/4/2011 16:22, prof. RNDr. Viktor Kanický, DrSc.
V originále
Experimentally contaminated archive agricultural soils (Central institute for Supervising and Testing in Agriculture - UKZUZ, Brno, Czech republic) were used to compare capabilities of energy dispersive XRF (XEPOS, Spectro, Germany, Turboquant software) ICP-OES (Ultrace JY-170, Jobin Yvon Horiba, France) of solutions obtained by means of decomposition with HCLO4 and HF. Bioavailability of Pb, Zn, Cu, Ni, Cr was examined using sequential extraction procedures. Finally, LA-ICPOES (UP-213 MACRO New Wave, USA; JY-170) method was established for analysis of contaminated soils. Certified reference material of soil (GBW07406) was employed to verify reliability of methods. Analysis of pulverized samples by LA-ICP-OES or LA-ICP-MS poses advantages and shortcomings at the same time: possibility of preparation of calibration samples of arbitrary composition, matrix matching and sample dilution, while problems involve sometimes laborious preparation of suitable compact targets and their satisfactory homogeneity. Influence of type of pellet preparation procedure, laser parameters (fluence, irradiated spot area) on analytical performance of LA-ICP-OES of soils are discussed.
In Czech
Experimentálně kontaminované půdní vzorky z archivívu Ústředního a kontrolního zkušebního ústavbu zemědělského Brno, CZ byly použity pro srovnání analýz pomocí energiově disperzní XRF (XEPOS, Spectro, Německo, Turboquant software), ICP-OES (Ultrace JY-170, Jobin Yvon Horiba, Francie) roztoků připravených rozkladem v HCLO4 a HF. Studovala se expozice živých tkání Pb, Zn, Cu, Ni, Cr sekvenční extrakcí. Kontaminace půd byla měřena pomocí LA-ICP-OES (UP-213 MACRO New Wave, USA; JY-170). Spolehlivost metod byla ověřena certifikovaným referenčním vzorkem půdy (GBW07406). Analýzy práškových vzorků půd pomocí LA-ICP-OEs či LA-ICP-MS mají výhody I nevýhody zároveň: lze připravit vzorek s libovolnou matricí, složením a naředěním, avšak problémy jsou s homogenizací vzorku a kompaktností tablety. Diskutuje se vliv přípravy tablety a parametrů ablace (fluence, velikost ozářené plochy) na výsledek analýzy LA-ICP-OES.
Links
MSM0021622410, plan (intention) |
| ||
MSM0021622412, plan (intention) |
|