Detailed Information on Publication Record
2008
Off-line capillary electrophoresis laser ablation inductively coupled plasma mass spectrometry for elemental speciation
PEŠ, Ondřej, Pavla FOLTYNOVÁ, Radek VYHNÁNEK, Tomáš VACULOVIČ, Viktor KANICKÝ et. al.Basic information
Original name
Off-line capillary electrophoresis laser ablation inductively coupled plasma mass spectrometry for elemental speciation
Name in Czech
Off-line spojení kapilární elektroforézy s laserovou ablací a hmotnostní spektrometrií indukčně vázaného plazmatu pro elementární speciace
Authors
PEŠ, Ondřej (203 Czech Republic, guarantor, belonging to the institution), Pavla FOLTYNOVÁ (203 Czech Republic, belonging to the institution), Radek VYHNÁNEK (203 Czech Republic, belonging to the institution), Tomáš VACULOVIČ (203 Czech Republic, belonging to the institution), Viktor KANICKÝ (203 Czech Republic, belonging to the institution) and Jan PREISLER (203 Czech Republic, belonging to the institution)
Edition
XIXth Slovak - Czech Spectroscopic Conference Book of Abstracts, 2008
Other information
Language
English
Type of outcome
Konferenční abstrakt
Field of Study
10406 Analytical chemistry
Country of publisher
Slovakia
Confidentiality degree
není předmětem státního či obchodního tajemství
RIV identification code
RIV/00216224:14310/08:00058786
Organization unit
Faculty of Science
ISBN
978-80-223-2557-8
Keywords in English
Capillary electrophoresis; mass spectrometry; ICP; speciation; chromium
Tags
International impact
Změněno: 9/4/2013 12:37, prof. Mgr. Jan Preisler, Ph.D.
V originále
On-line combination of capillary electrophoresis (CE) and sensitive, element-selective, inductively coupled plasma (ICP) and mass spectrometry (MS) is commonly based on a nebulizer interface for direct linking to ICP torch, resulting in reducing the electrophoretic resolution due to pressure-induced flow caused by the nebulizer. In our approach, CE fractions are collected on a suitable target and the entire separation record is analyzed by laser ablation/desorption (LA/LD) ICP MS.
In Czech
On-line kombinace CE a ICP MS se bežně používá pro citlivou elementárně specifickou detekci. Všechny spojení jsou založené na přímém spojení přes nebulizér, což vede ke snížení rozlišení v důsledku indukovaného tlaku v kapiláře. Náš přístup spočívá ve sbírání frakcí na vhodný substrát a celý separační záznam je analyzován v off-line módu za využití laserové ablace/desorpce ICP MS.
Links
LC06035, research and development project |
| ||
MSM0021622411, plan (intention) |
| ||
MSM0021622412, plan (intention) |
| ||
MSM0021622415, plan (intention) |
|