D 2008

METALLOTHIONEIN-CISPLATIN INTERACTION REVEALED BY QUARTZ CRYSTAL AND MERCURY ELECTRODE

KŘÍŽKOVÁ, Soňa, Ivo FABRIK, Violetta SHESTIVSKA, Tomáš ECKSCHLAGER, Jan HRABĚTA et. al.

Basic information

Original name

METALLOTHIONEIN-CISPLATIN INTERACTION REVEALED BY QUARTZ CRYSTAL AND MERCURY ELECTRODE

Name in Czech

Interakce metalothioneinu s cisplatinou odhalené pomocí křemíkového krystalu a rtuťové elektrody

Authors

KŘÍŽKOVÁ, Soňa (203 Czech Republic), Ivo FABRIK (203 Czech Republic), Violetta SHESTIVSKA (203 Czech Republic), Tomáš ECKSCHLAGER (203 Czech Republic), Jan HRABĚTA (203 Czech Republic), Vojtěch ADAM (203 Czech Republic), Libuše TRNKOVÁ (203 Czech Republic) and René KIZEK (203 Czech Republic, guarantor)

Edition

Brno, Electrochemistry of Nucleic Acids and Proteins. Book of Abstracts, p. 78-78, 1 pp. 2008

Publisher

Biofyzikální ústav AV ČR, v.v.i.

Other information

Language

English

Type of outcome

Stať ve sborníku

Field of Study

10405 Electrochemistry

Country of publisher

Czech Republic

Confidentiality degree

není předmětem státního či obchodního tajemství

RIV identification code

RIV/00216224:14310/08:00024315

Organization unit

Faculty of Science

Keywords in English

cisplatin; metallothionein; differential pulse voltammetry; quartz crystal
Změněno: 10/11/2008 13:31, prof. RNDr. Libuše Trnková, CSc.

Abstract

V originále

The aim of this work was to investigate the interactions of metallothioneins with cisplatin. For this purpose we employed adsorptive transfer stripping technique with differential pulse voltammetry (mercury electrode) and gravimetric measurements (quartz crystal). Primarily we optimized experimental conditions for determination of MT using both techniques. The average concentration of the drug bound to DNA was estimated as 8.1 ng of cisplatin per 500 ng of DNA by voltammetry. Gravimetric measurements gave very similar results.

In Czech

Cílem této práce bylo studium interakcí metalothioneinů (MT) s cisplatinou. K tomu byla využia adsorptivní přenosová rozpouštěcí technika s diferenční pulsní voltametrií (rtuťová elektroda) a gravimetrické měření. Nejprve jsme optimalizovali experimentální podmínky pro stanovení MT oběma metodami. Průměrná koncentrace cis-Pt vázané na DNA byla voltametricky stanovena na 8.1 ng cis-Pt na 500 ng DNA. Gravimetrické měření mělo velmi podobné výsledky.

Links

IAA401990701, research and development project
Name: Studium vazby platinových cytostatik do struktury DNA; Vliv metalothioneinu