Detailed Information on Publication Record
2008
Amperometric sensor for detection of chloride ions
TRNKOVÁ, Libuše, Vojtěch ADAM, Jaromír HUBÁLEK, Petr BABULA, René KIZEK et. al.Basic information
Original name
Amperometric sensor for detection of chloride ions
Name in Czech
Amperometrický senzor pro detekci chloridových iontů
Authors
TRNKOVÁ, Libuše (203 Czech Republic, guarantor), Vojtěch ADAM (203 Czech Republic), Jaromír HUBÁLEK (203 Czech Republic), Petr BABULA (203 Czech Republic) and René KIZEK (203 Czech Republic)
Edition
Sensors, Basel, Switzerland, MOLECULAR DIVERSITY PRESERVATION INT, 2008, 1424-8220
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10405 Electrochemistry
Country of publisher
Switzerland
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 1.870
RIV identification code
RIV/00216224:14310/08:00034075
Organization unit
Faculty of Science
UT WoS
000259735700022
Keywords in English
chloride ions; silver; voltammetry; amperometry
Tags
Změněno: 14/7/2009 13:45, prof. RNDr. Libuše Trnková, CSc.
V originále
Chloride ion sensing is important in many fields such as clinical diagnosis, environmental monitoring and industrial applications. We have measured chloride ions at a carbon paste electrode (CPE) and at a CPE modified with solid AgNO3, a solution of AgNO3 and/or solid silver particles. Detection limits (3 S/N) for chloride ions were 100 mu M, 100 mu M and 10 mu M for solid AgNO3, solution of AgNO3 and/or solid silver particles, respectively. The CPE modified with silver particles is the most sensitive to the presence chloride ions. After that we approached to the miniaturization of the whole electrochemical instrument. Measurements were carried out on miniaturized instrument consisting of a potentiostat with dimensions 35 x 166 x 125 mm, screen printed electrodes, a peristaltic pump and a PC with control software. Under the most suitable experimental conditions (Britton-Robinson buffer, pH 1.8 and working electrode potential 550 mV) we estimated the limit of detection (3 S/N) as 500 nM.
In Czech
Stanovení chloridových iontů je důležité v mnoha oborech, jako je např. klinická diagnostika, monitoring životního prostředí a průmyslové aplikace. Měřili jsme chloridové ionty na uhlíkové pastové elektrodě (CPE) a na CPE modifikované pevným AgNO3, roztokem AgNO3 a/nebo stříbrnými částicemi. Detekční limit v optimálních podmínkách byl stanoven jako 500 nM.
Links
MSM0021622412, plan (intention) |
|