Detailed Information on Publication Record
2008
Investigation of heavy-metal accumulation in selected plant samples using laser induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry
GALIOVÁ, Michaela, Jozef KAISER, Karel NOVOTNÝ, Jan NOVOTNÝ, Tomáš VACULOVIČ et. al.Basic information
Original name
Investigation of heavy-metal accumulation in selected plant samples using laser induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry
Name in Czech
Zjištování akumulace težkých kovů ve vybraných rostlinách s použitím spektrometrie laserem buzeného plazmatu a laserové ablace ve spojení s hmotnostní spektrometrií indukčně vázaného plazmatu
Authors
GALIOVÁ, Michaela (203 Czech Republic, belonging to the institution), Jozef KAISER (203 Czech Republic), Karel NOVOTNÝ (203 Czech Republic, guarantor, belonging to the institution), Jan NOVOTNÝ (203 Czech Republic), Tomáš VACULOVIČ (203 Czech Republic, belonging to the institution), Miroslav LIŠKA (203 Czech Republic), Radomír MALINA (203 Czech Republic), Karel STEJSKAL (203 Czech Republic, belonging to the institution), Vojtěch ADAM (203 Czech Republic) and René KIZEK (203 Czech Republic, belonging to the institution)
Edition
Applied Physics A: Materials Science & Processing, Berlin, Springer-Verlag, 2008, 0947-8396
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10406 Analytical chemistry
Country of publisher
Germany
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 1.884
RIV identification code
RIV/00216224:14310/08:00026816
Organization unit
Faculty of Science
UT WoS
000260218500017
Keywords in English
LIBS; LA-ICP-MS; laser ablation; mass-spectrometry; heavy-metal accumulation
Tags
International impact, Reviewed
Změněno: 10/1/2011 15:12, Mgr. Michaela Vašinová Galiová, Ph.D.
V originále
Single-pulse Laser Induced Breakdown Spectroscopy (LIBS) and Laser - Ablation Inductively Coupled Plasma Mass-Spectrometry (LA-ICP-MS) were applied for mapping the silver and copper distribution in Helianthus Annuus L. samples treated with contaminant in controlled conditions. For Ag and Cu detection the 328.07 nm Ag(I) and 324.75 nm Cu(I) lines were used, respectively. The LIBS experimental conditions (mainly the laser energy and the observation window) were optimized in order to avoid self-absorption effect in the measured spectra. In the LA-ICP-MS analysis the Ag 107 and Cu 63 isotopes were detected. The capability of these two analytical techniques for high-resolution mapping of selected trace chemical elements was demonstrated.
In Czech
Spektrometrie laserem buzeného plazmatu v single pulse režimu (LIBS) a laserová ablace ve spojení s hmotnostní spektrometrií indukčně vázaného plazmatu (LA-ICP-MS) byla použita pro mapování distribuce stříbra a mědi v listech slunečnice (Helianthus Annuus L.), která byla pěstována za řízených podmínek v prostředí obsahující výše uvedené kontaminanty. Pro detekci Ag byla použita emisní atomová čára 328.07 nm, pro měď pak atomová čára 324.75 nm. Experimentální podmínky pro LIBS spektrometrii (energie laseru, zpoždění a doba detekce) byly optimalizovány tak, aby byla minimalizována možnost samoabsorpce. V případě LA-ICP-MS byly detekovány isotopy Ag 107 a Cu 63. Možnosti těchto dvou analytických technik byly demonstrovány na mapování vybraných stopových prvků s vysokým prostorovým rozlišením.
Links
MSM0021622411, plan (intention) |
|