Detailed Information on Publication Record
2008
Spatially resolved laser induced breakdown spectroscopy in orthogonal double pulse configuration and laser ablation inductively coupled plasma mass spectrometry of archaeological findings
HRDLIČKA, Aleš, Lubomír PROKEŠ, Karel NOVOTNÝ, Veronika KONEČNÁ, Viktor KANICKÝ et. al.Basic information
Original name
Spatially resolved laser induced breakdown spectroscopy in orthogonal double pulse configuration and laser ablation inductively coupled plasma mass spectrometry of archaeological findings
Name in Czech
Prostorově rozlišená analýza spektroskopií laserem vybuzeného mikroplazmatu v ortogonálním uspořádání a laserová ablace s indukčně vázaným plazmatem a hmotnostní spektrometríí archeologických nálezů
Authors
HRDLIČKA, Aleš (203 Czech Republic, guarantor), Lubomír PROKEŠ (203 Czech Republic), Karel NOVOTNÝ (203 Czech Republic), Veronika KONEČNÁ (203 Czech Republic), Viktor KANICKÝ (203 Czech Republic) and Vítězslav OTRUBA (203 Czech Republic)
Edition
Chemické listy, 2008, 1213-7103
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10402 Inorganic and nuclear chemistry
Country of publisher
Czech Republic
Confidentiality degree
není předmětem státního či obchodního tajemství
References:
Impact factor
Impact factor: 0.593
RIV identification code
RIV/00216224:14310/08:00027003
Organization unit
Faculty of Science
UT WoS
000208452600015
Keywords in English
laser ablation; inductively coupled; plasma; mass spectrometry; laser induced; breakdown spectrometry; orthogonal; double pulse; archaeological; tooth;
Tags
Změněno: 15/12/2008 16:41, Mgr. Aleš Hrdlička, Ph.D.
V originále
The presented comparison of DPLIBS with LA-ICP-MS and with already published results showed that the DPLIBS method in the presented particular orthogonal configuration can be successfully used for the mapping of the spatial distributions of biologically important elements as Ca, Mg, Sr, Zn. It can be applied as a suitable alternative to the routinely used LA-ICP-MS method due to the sufficient spatial resolution and sensitivity to the minor elements. These properties are not obtainable for single pulse LIBS.
In Czech
Srovnání metody double pulse LIBS s LA-ICP-MS a s dosud publikovanými výsledky ukázalo, že použité ortogonální uspořádání je využitelné pro mapování prostorového rozložení biologicky důležitých prvků jako Ca, Mg, Sr, Zn. Díky dostatečnému prostorovému rozlišení a citlivosti na minoritní prvky tak může být vhodnou alternativou k běžně užívanému LA-ICP-MS narozdíl od jednoduché metody LIBS.
Links
ME08002, research and development project |
| ||
MSM0021622411, plan (intention) |
|