MICKOVÁ, A., K. TOMÁNKOVÁ, H. KOLÁŘOVÁ, R. BAJGAR, P. KOLÁŘ, Pavel ŠUNKA, P. PLENCNER, M. JAKUBOVÁ, J. BENEŠ, L. KOLÁČNÁ, Ladislav PLÁNKA, Alois NEČAS and E. AMLER. Ultrasonic Shock-Wave as a Control Mechanism for Liposome Drug Delivery System for Possible Use in Scaffold Implanted to Animals with Iatrogenic Articular Cartilage Defects. Acta Veterinaria. Brno, 2008, vol. 77, No 2, p. 285-290, 5 pp. ISSN 0001-7213.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Ultrasonic Shock-Wave as a Control Mechanism for Liposome Drug Delivery System for Possible Use in Scaffold Implanted to Animals with Iatrogenic Articular Cartilage Defects
Name in Czech Ultrazvukové vlny jako kontrolní mechanismus pro uvolňování účinných látek z lipozomů použité u skafoldů implantovaných do iatrogenního defektu kloubní chrupavky
Authors MICKOVÁ, A. (203 Czech Republic), K. TOMÁNKOVÁ (203 Czech Republic), H. KOLÁŘOVÁ (203 Czech Republic), R. BAJGAR (203 Czech Republic), P. KOLÁŘ (203 Czech Republic), Pavel ŠUNKA (203 Czech Republic), P. PLENCNER (203 Czech Republic), M. JAKUBOVÁ (203 Czech Republic), J. BENEŠ (203 Czech Republic), L. KOLÁČNÁ (203 Czech Republic), Ladislav PLÁNKA (203 Czech Republic, guarantor), Alois NEČAS (203 Czech Republic) and E. AMLER (203 Czech Republic).
Edition Acta Veterinaria, Brno, 2008, 0001-7213.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 30211 Orthopaedics
Country of publisher Czech Republic
Confidentiality degree is not subject to a state or trade secret
Impact factor Impact factor: 0.395
RIV identification code RIV/00216224:14110/08:00027073
Organization unit Faculty of Medicine
UT WoS 000257226400019
Keywords in English Liposome;controlled drug delivery;ultrasound shock-wave;fluorescence
Tags controlled drug delivery, fluorescence, Liposome, ultrasound shock-wave
Tags International impact, Reviewed
Changed by Changed by: prof. MUDr. Ladislav Plánka, Ph.D., učo 20583. Changed: 25/6/2009 11:49.
Abstract
A short liposome exposure to ultrasonic waves with the intensity of I = 2 W/cm2 at frequency f = 1 MHz was found to be a sufficient tool for liposome opening. In addition, shock-wave proved to be sufficient also for liposome content release. Both methods are useful tools to be used as control mechanisms for drug delivery systems based on liposomes. However, due to better focusing and low non-thermal side effects, shock-waves probably have a markedly higher potential for successful use.
Abstract (in Czech)
Krátkodobá expozice UZ vln o intenzitě 2 W/cm2 a frekvenci 1 MHz byla pozorována jako dostatečná pro otevření lopozomů, stejně jako šoková stimulace UZ vlnami. Obě metody mohou sloužit jako kontrolní mechanismus pro uvolňování účinných látek z lipozomů použité u skafoldů implantovaných do iatrogenního defektu kloubní chrupavky