Ultrasonic Shock-Wave as a Control Mechanism for Liposome Drug Delivery System for Possible Use in Scaffold Implanted to Animals with Iatrogenic Articular Cartilage Defects

MICKOVÁ, A., K. TOMÁNKOVÁ, H. KOLÁŘOVÁ, R. BAJGAR, P. KOLÁŘ et. al.

Basic information

Original name

Ultrasonic Shock-Wave as a Control Mechanism for Liposome Drug Delivery System for Possible Use in Scaffold Implanted to Animals with Iatrogenic Articular Cartilage Defects

Name in Czech

Ultrazvukové vlny jako kontrolní mechanismus pro uvolňování účinných látek z lipozomů použité u skafoldů implantovaných do iatrogenního defektu kloubní chrupavky

Authors

MICKOVÁ, A. (203 Czech Republic), K. TOMÁNKOVÁ (203 Czech Republic), H. KOLÁŘOVÁ (203 Czech Republic), R. BAJGAR (203 Czech Republic), P. KOLÁŘ (203 Czech Republic), Pavel ŠUNKA (203 Czech Republic), P. PLENCNER (203 Czech Republic), M. JAKUBOVÁ (203 Czech Republic), J. BENEŠ (203 Czech Republic), L. KOLÁČNÁ (203 Czech Republic), Ladislav PLÁNKA (203 Czech Republic, guarantor), Alois NEČAS (203 Czech Republic) and E. AMLER (203 Czech Republic)

Edition

Acta Veterinaria, Brno, 2008, 0001-7213

Other information

Language

English

Type of outcome

Článek v odborném periodiku

Field of Study

30211 Orthopaedics

Country of publisher

Czech Republic

Confidentiality degree

není předmětem státního či obchodního tajemství

Impact factor

Impact factor: 0.395

RIV identification code

RIV/00216224:14110/08:00027073

Organization unit

Faculty of Medicine

UT WoS

000257226400019

Keywords in English

Liposome;controlled drug delivery;ultrasound shock-wave;fluorescence

Tags

International impact, Reviewed
Změněno: 25/6/2009 11:49, prof. MUDr. Ladislav Plánka, Ph.D.

Abstract

V originále

A short liposome exposure to ultrasonic waves with the intensity of I = 2 W/cm2 at frequency f = 1 MHz was found to be a sufficient tool for liposome opening. In addition, shock-wave proved to be sufficient also for liposome content release. Both methods are useful tools to be used as control mechanisms for drug delivery systems based on liposomes. However, due to better focusing and low non-thermal side effects, shock-waves probably have a markedly higher potential for successful use.

In Czech

Krátkodobá expozice UZ vln o intenzitě 2 W/cm2 a frekvenci 1 MHz byla pozorována jako dostatečná pro otevření lopozomů, stejně jako šoková stimulace UZ vlnami. Obě metody mohou sloužit jako kontrolní mechanismus pro uvolňování účinných látek z lipozomů použité u skafoldů implantovaných do iatrogenního defektu kloubní chrupavky