Ultrasonic Shock-Wave as a Control Mechanism for Liposome Drug Delivery System for Possible Use in Scaffold Implanted to Animals with Iatrogenic Articular Cartilage Defects
MICKOVÁ, A., K. TOMÁNKOVÁ, H. KOLÁŘOVÁ, R. BAJGAR, P. KOLÁŘ et. al.Basic information
Original name
Ultrasonic Shock-Wave as a Control Mechanism for Liposome Drug Delivery System for Possible Use in Scaffold Implanted to Animals with Iatrogenic Articular Cartilage Defects
Name in Czech
Ultrazvukové vlny jako kontrolní mechanismus pro uvolňování účinných látek z lipozomů použité u skafoldů implantovaných do iatrogenního defektu kloubní chrupavky
Authors
MICKOVÁ, A. (203 Czech Republic), K. TOMÁNKOVÁ (203 Czech Republic), H. KOLÁŘOVÁ (203 Czech Republic), R. BAJGAR (203 Czech Republic), P. KOLÁŘ (203 Czech Republic), Pavel ŠUNKA (203 Czech Republic), P. PLENCNER (203 Czech Republic), M. JAKUBOVÁ (203 Czech Republic), J. BENEŠ (203 Czech Republic), L. KOLÁČNÁ (203 Czech Republic), Ladislav PLÁNKA (203 Czech Republic, guarantor), Alois NEČAS (203 Czech Republic) and E. AMLER (203 Czech Republic)
Edition
Acta Veterinaria, Brno, 2008, 0001-7213
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
30211 Orthopaedics
Country of publisher
Czech Republic
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 0.395
RIV identification code
RIV/00216224:14110/08:00027073
Organization unit
Faculty of Medicine
UT WoS
000257226400019
Keywords in English
Liposome;controlled drug delivery;ultrasound shock-wave;fluorescence
Tags
International impact, Reviewed
Změněno: 25/6/2009 11:49, prof. MUDr. Ladislav Plánka, Ph.D.
V originále
A short liposome exposure to ultrasonic waves with the intensity of I = 2 W/cm2 at frequency f = 1 MHz was found to be a sufficient tool for liposome opening. In addition, shock-wave proved to be sufficient also for liposome content release. Both methods are useful tools to be used as control mechanisms for drug delivery systems based on liposomes. However, due to better focusing and low non-thermal side effects, shock-waves probably have a markedly higher potential for successful use.
In Czech
Krátkodobá expozice UZ vln o intenzitě 2 W/cm2 a frekvenci 1 MHz byla pozorována jako dostatečná pro otevření lopozomů, stejně jako šoková stimulace UZ vlnami. Obě metody mohou sloužit jako kontrolní mechanismus pro uvolňování účinných látek z lipozomů použité u skafoldů implantovaných do iatrogenního defektu kloubní chrupavky