Detailed Information on Publication Record
2008
Capillary immunotyping electrophoresis and high resolution two-dimensional electrophoresis for the detection of mu-heavy chain disease.
MAISNAR, Vladimír, Miloš TICHÝ, J. STULÍK, P. URBAN, Zdeněk ADAM et. al.Basic information
Original name
Capillary immunotyping electrophoresis and high resolution two-dimensional electrophoresis for the detection of mu-heavy chain disease.
Name in Czech
Užití kapilární a dvourozměrné elektroforézy pro stanovení mu těžkých řetězců
Authors
MAISNAR, Vladimír (203 Czech Republic), Miloš TICHÝ (203 Czech Republic), J. STULÍK (203 Czech Republic), P. URBAN (203 Czech Republic), Zdeněk ADAM (203 Czech Republic, guarantor), Eva KDLČKOVÁ (203 Czech Republic), J. VÁVROVÁ (203 Czech Republic), Vladimír PALIČKA (203 Czech Republic), L. JEBAVÝ (203 Czech Republic), R. KODET (203 Czech Republic), Tomáš BÜCHLER (203 Czech Republic) and Roman HÁJEK (203 Czech Republic)
Edition
Clinica Chimica Acta, Amsterdam, Elsevier Science BV, 2008, 0009-8981
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
30200 3.2 Clinical medicine
Country of publisher
Netherlands
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 2.960
RIV identification code
RIV/00216224:14110/08:00034898
Organization unit
Faculty of Medicine
UT WoS
000253450300030
Keywords (in Czech)
mnohočetný myelom; monoklonální imunoglobulin;imunofixace
Keywords in English
multiple myeloma;monoclonal immunoglobulin;immunofixation
Tags
International impact, Reviewed
Změněno: 29/6/2009 13:21, Ing. Gabriela Petrovičová
V originále
Heavy chain disease with monoclonal incomplete mu-heavy chains (mu-HCD) is a rare disorder usually associated with an underlying lymphoproliferative malignancy. Laboratory diagnosis of patients with mu-HCD is usually challenging and the monoclonal protein is not detected by electrophoresis in up to 75% of mu-HCD cases. We describe a patient with multiple malignancies in whom we detected and characterized monoclonal mu-heavy chains using immunofixation electrophoresis, capillary zone electrophoresis with immunotyping, and high resolution two-dimensional electrophoresis. The high resolution 2D electrophoresis enabled us to determine the molecular weight of the mu-heavy chains. The abnormal protein concentration in the serum was unusually high, 38 g/l measured in our patient is the highest reported value in the literature so far.
In Czech
V této práce je popsáno užití kapilární a dvourozměrné elektroforézy pro stanovení mu těžkých řetězců.