Detailed Information on Publication Record
2006
International Staging System required standardization of biochemical laboratory testing in multiple myeloma
TICHÝ, M., Vladimír MAISNAR, Vladimír PALIČKA, Bedřich FRIEDECKÝ, J. VÁVROVÁ et. al.Basic information
Original name
International Staging System required standardization of biochemical laboratory testing in multiple myeloma
Name in Czech
Standardizace biochemických laboratorních markerů pro diagnostiku mnohočetného myelomu
Authors
TICHÝ, M. (203 Czech Republic), Vladimír MAISNAR (203 Czech Republic), Vladimír PALIČKA (203 Czech Republic), Bedřich FRIEDECKÝ (203 Czech Republic), J. VÁVROVÁ (203 Czech Republic), H. NOVOTNÁ (203 Czech Republic), Z. ČERMÁKOVÁ (203 Czech Republic), M. DASTYCH (203 Czech Republic), P. ČECHÁK (203 Czech Republic), D. VOGTOVÁ (203 Czech Republic), E. JAROLÍMKOVÁ (203 Czech Republic), H. BENÁKOVÁ (203 Czech Republic), L. HACHOVÁ (203 Czech Republic), D. BEZDÍČKOVÁ (203 Czech Republic), F. KOUŘIL (203 Czech Republic), EA. ZÁBRANSKÁ (203 Czech Republic), J. ZENKOVÁ (203 Czech Republic), P. SLABÝ (203 Czech Republic), V. ŠČUDLA (203 Czech Republic), E. GREGORA (203 Czech Republic), Ivan ŠPIČKA (203 Czech Republic), J. ŠTRAUB (203 Czech Republic), M. SCHÜTZOVÁ (203 Czech Republic) and Roman HÁJEK (203 Czech Republic, guarantor)
Edition
Neoplasma, Slovakia, Slovak Academic Press Ltd. 2006, 0028-2685
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
30200 3.2 Clinical medicine
Country of publisher
Slovakia
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 1.247
RIV identification code
RIV/00216224:14110/06:00035892
Organization unit
Faculty of Medicine
UT WoS
000243359900006
Keywords (in Czech)
mnohočetný myelom;
Keywords in English
multiple myeloma;
Tags
Tags
Reviewed
Změněno: 23/6/2009 07:45, Mgr. Anna Potáčová, Ph.D.
V originále
The standardization of biochemical measurement procedures in multiple myeloma is necessary for reliable prognostic stratification of patients in multicentric trials. The new prognostic index International Staging System for multiple myeloma uses only two laboratory markers, albumin and beta-2 microglobulin. Our study compared results of albumin, beta-2 microglobulin and monoclonal immunoglobulin measurements from six centers which provide treatment for multiple myeloma in the Czech Republic and attempted to standardize the analytic procedures. We have found that the measurement of albumin is well standardized and the results from all laboratories were comparable. The measurement of beta-2 microglobulin achieved comparability only after a partial unification of analytical methods. The determination of monoclonal immunoglobulin concentration provided comparable results for concentrations higher than 20 g/l with higher variability for lower values.
In Czech
V této práci jsou porovnány výsledky stanovování laboratorních markerů (albuminu, monoklonálního imunoglobulinu a beta-2 mikroglobulinu) z 6 center v České republice.