NOVOTNÝ, Jan, Radomír MALINA, Jozef KAISER, Miroslav LIŠKA, Michaela GALIOVÁ and Karel NOVOTNÝ. Implementation of an autofocus algorithm based on searching the best in-focus image into a table-top laser-induced breakdown spectroscopy setup. Optical Engineering. 2009, vol. 48, No 10, 10 pp. ISSN 0091-3286.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Implementation of an autofocus algorithm based on searching the best in-focus image into a table-top laser-induced breakdown spectroscopy setup
Name in Czech Začlenění autofokusačního algoritmu založeném na hledání nejostřejšího obrazu do stolního uspořádání spektrometrie laserem buzeného plazmatu
Authors NOVOTNÝ, Jan (203 Czech Republic), Radomír MALINA (203 Czech Republic), Jozef KAISER (203 Czech Republic), Miroslav LIŠKA (203 Czech Republic), Michaela GALIOVÁ (203 Czech Republic) and Karel NOVOTNÝ (203 Czech Republic, guarantor).
Edition Optical Engineering, 2009, 0091-3286.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10306 Optics
Country of publisher United States of America
Confidentiality degree is not subject to a state or trade secret
Impact factor Impact factor: 0.553
RIV identification code RIV/00216224:14310/09:00037271
Organization unit Faculty of Science
UT WoS 000271746200009
Keywords (in Czech) automatické zaostřování; autofokusace; ostrost obrazu; spektrometrie laserem buzeného plazmatu; Fourierova transformace; Pearsonova korelace; digitální šum
Keywords in English automatic focusing; autofocus; image sharpness; laser induced breakdown spectroscopy; Fourier transform; Pearson correlation; digital noise
Tags International impact, Reviewed
Changed by Changed by: doc. Mgr. Karel Novotný, Ph.D., učo 17748. Changed: 8/2/2010 19:01.
Abstract
Laser-ablation based spectrochemical analytical methods could be used in applications in which the capability for spatially resolved analysis is required. Such analysis gives a 2-D or 3-D map of the monitored chemical elements. Here we introduce automation of a 2-D surface analysis in the laser-induced breakdown spectroscopy setup by implementation of an autofocus algorithm based on the evaluation of the image sharpness. The most suitable algorithm with respect to its speed, accuracy, and durability against digital noise is chosen by testing different gradient-based methods and methods working in the frequency domain.
Abstract (in Czech)
V případech, kdy je požadována analýza s prostorovým rozlišením, mohou být použity analytické techniky založené na laserové ablaci. Taková analýza poskytuje informaci o 2-D nebo 3-D rozložení sledovaných prvků. V článku je presentována automatická 2-D povrchová analýza pomocí spektrometrie laserem buzeného plazmatu se začleněním autofokusačního algoritmu založeném na analýze ostrosti obrazu. Nejvhodnější algoritmus byl vybrán s ohledem na rychlost, přesnost a odolnost proti digitálnímu šumu.
Links
MSM0021622411, plan (intention)Name: Studium a aplikace plazmochemických reakcí v neizotermickém nízkoteplotním plazmatu a jeho interakcí s povrchem pevných látek
Investor: Ministry of Education, Youth and Sports of the CR, Study and application of plasma chemical reactions in non-isothermic low temperature plasma and its interaction with solid surface
PrintDisplayed: 2/9/2024 06:06